STEAM CONNECTION - (STANDARD or HR ONLY)
STEAM
•
CHECK THE STEAM SUPPLY PRESSURE REQUIREMENTS PRIOR TO CONNECTING THE
STEAM SUPPLY LINE.
•
CHECK THE STEAM SUPPLY PRESSURE REQUIREMENTS PRIOR TO CONNECTING THE
STEAM SUPPLY LINE.
•
1" NPT SUPPLY LINE FOR WASH TANK 3/4" SUPPLY LINE FOR BOOSTER.
•
STEAM CONNECTION IS LOCATED ON THE SIDE OF THE MACHINE.
•
STEAM CONDENSATE LINE IS 3/4" NPT FOR MACHINE, 1/2" NPT FOR BOOSTER.
•
CONDENSATE LINES MUST BE GRAVITY DRAIN WITH NO BACK PRESSURE. A
CONDENSATE LIFT PUMP MAY BE REQUIRED IF LINE IS ABOVE THE BASE OF THE
MACHINE.
STEAM CONSUMPTION
•
TANK HEAT - LBS./HR. REQUIRED AT 15 PSI = 125 LBS./HR.
•
STEAM BOOSTER - LBS./HR. REQUIRED 70ºF/21.1ºC @ 15 PSI = 110 LBS./HR.
•
WATER HARDNESS OF 3 GRAINS/US GAL - 0.83 IMP GAL - 5.3 MG/L or LESS
Fig. 10 - Steam inlet.
Fig. 11 - Condensate return.
Installation
11