Steam Connection - (Standard And Hr Only); Steam Consumption - Champion 64 PRO Series Installation Manual

Two tank rack conveyor dishwasher
Table of Contents

Advertisement

STEAM CONNECTION - (STANDARD or HR ONLY)
STEAM
CHECK THE STEAM SUPPLY PRESSURE REQUIREMENTS PRIOR TO CONNECTING THE
STEAM SUPPLY LINE.
CHECK THE STEAM SUPPLY PRESSURE REQUIREMENTS PRIOR TO CONNECTING THE
STEAM SUPPLY LINE.
1" NPT SUPPLY LINE FOR WASH TANK 3/4" SUPPLY LINE FOR BOOSTER.
STEAM CONNECTION IS LOCATED ON THE SIDE OF THE MACHINE.
STEAM CONDENSATE LINE IS 3/4" NPT FOR MACHINE, 1/2" NPT FOR BOOSTER.
CONDENSATE LINES MUST BE GRAVITY DRAIN WITH NO BACK PRESSURE. A
CONDENSATE LIFT PUMP MAY BE REQUIRED IF LINE IS ABOVE THE BASE OF THE
MACHINE.

STEAM CONSUMPTION

TANK HEAT - LBS./HR. REQUIRED AT 15 PSI = 125 LBS./HR.
STEAM BOOSTER - LBS./HR. REQUIRED 70ºF/21.1ºC @ 15 PSI = 110 LBS./HR.
WATER HARDNESS OF 3 GRAINS/US GAL - 0.83 IMP GAL - 5.3 MG/L or LESS
Fig. 10 - Steam inlet.
Fig. 11 - Condensate return.
Installation
11

Advertisement