Part 2: INSTALLATION

2.6 Water Connections

Perform the following steps to connect the water supply
Refer to Figure 2.3 on the next page.
WARNING:
The installation of water supplies must conform to local codes or, in the absence of local code,
all National Codes governing plumbing, sanitation, safety and good trade practices.
1. Connect a 3/4" NPT hot water supply line (110 F minimum) to the water inlet valve located
at the booster. (See No. 1, Fig. 2.3.)
2. Connect a 1/2" NPT hot water line (140 F minimum) to the water inlet valve located at the
top of the dishwasher. (See No. 2, Fig. 2.3.)

2.7 Steam and Condensate Connections (Steam heat only)

Perform the following steps to connect the steam supply and condensate return.
Refer to Figure 2.3 on the next page.
WARNING:
The installation of steam supplies must conform to local codes or, in the absence of local code,
all National Codes governing plumbing, sanitation, safety and good trade practices.
NOTE:
A manual shut-off valve for steam (supplied by others) should be installed in the supply lines
to allow for servicing of the machine. The shut-off valve should be the same size or larger
than the supply line.
1. Connect a 1-1/2" NPT steam supply line to the line strainer located at the booster.
(See No. 3, Fig 2.3)
2. Connect a 1" NPT steam condensate line to the tee fitting located at the booster.
Condensate must be gravity return to the boiler or to a pumping trap.
(See No. 4, Fig. 2.3)