Ventilation - Vent Hood Fan Control; Ventilation - Pant Leg Duct Setting - Champion 64 PRO Series Installation Manual

Two tank rack conveyor dishwasher
Table of Contents

Advertisement

Installation

VENTILATION - VENT HOOD FAN CONTROL

Standard model installations using an approved vent hood may require a vent
fan signal. This signal is supplied by the dishwasher control circuit. A qualified
installer must connect a signal circuit to the fuse holder and a common
neutral terminal provided. See Fig. 15.
CAUTION:
not connect the vent fan motor to Line Power 120VAC,
1.0 Amp fused connection terminals. The fused 120VAC
Line Power only supplies an external vent fan contactor
(supplied by others), and is limited to 1.0 AMP maximum
load. The 120VAC is powered whenever main power is on.
PANT LEG DUCT SETTING
LOAD END = 200CFM @ 1/4" SP, 71L/SEC.
UNLOAD END = 400CFM @ 1/4" SP, 189L/SEC.
ADEQUATE AIR CHANGES SHOULD BE CONSIDERED
BY THE HVAC CONTRACTOR.
4" X 16" VENT STACKS WITH ADJUSTABLE DAMPERS ARE
SUPPLIED BY FACTORY.
NOTE:
Loosen the wing-nut holding the damper handle
and turn it to open or close the damper to adjust
the steam exiting the machine.
14
To prevent damage to the dishwasher do
1.0A
Fig. 15 - Connection is
located inside the top
control cabinet.
Damper
Handle
Wing-nut
Fig. 16 - Duct.

Advertisement

Table of Contents
loading

Table of Contents