Installation
HEAT RECOVERY, HR, COLD WATER CONNECTION
COLD
WATER
CAUTION:
plumber must thoroughly flush debris from the water supply line before
connecting it to the dishwasher. Damage caused by improper installation is not
covered by the limited warranty.
•
INCOMING WATER TEMPERATURE = 55-75ºF/12.7- 23.8ºC.
•
WATER HARDNESS OF 3 GRAINS/US GAL - 0.83 IMP GAL - 5.3 MG/L or LESS
•
INSTALL A 3/4" NPT OR LARGER SHUT-OFF VALVE IN THE WATER SUPPLY LINE AS CLOSE
TO THE DISHWASHER FOR SERVICING.
•
WATER SUPPLY CONNECTION IS LOCATED AT REAR OF MACHINE AT THE UNLOAD END
OF THE MACHINE.
1/2" NPT
Cold Water
Fig. 9 - Heat Recovery Cold Water Connection.
10
•
MINIMUM 1/2" NPT COLD WATER SUPPLY LINE.
•
MINIMUM INCOMING FLOW PRESSURE = 55 PSI/379.2
•
PRV REQUIRED IF INCOMING PRESSURE EXCEEDS 60 PSI/413.7 kPa
To prevent damage to the dishwasher supply valves, the installing
kPa