Heat Pump, (HP), Mounting Instructions
for PRO-VHR Rack Conveyor Dishwashers
CAUTION:
The HP weighs 300 lbs./136 kg. Use 4 people to lift.
Fasteners:
(18) 1/4-20 x 1/2" Hex Hd. Bolts, P/N 100734
(18) 1/4" Split Lock Washers, P/N 106482
(18) 1/4" Flat Washers, P/N 106026
Perform steps below to mount the HP:
Step 1:
Remove the panels, (yellow outline),
before lifting.
Step 2:
Place the HP on dishwasher, (red outline).
Secure using supplied fasteners.
Step 3:
Install quick connect plug on top of machine
behind fan (Fig. 2).
Step 4:
Install compressor cable bracket on back
of machine below the HP. (Fig. 3).
Step 5:
Plug compressor cable into front of
compressor behind the insulation (Fig. 4).
Step 6:
Reinstall panels. Mounting complete.