Installation
Cold Water Connection for All Machines with
Drain Water Tempering, (DWT), Valve
COLD
WATER
CAUTION:
plumber must thoroughly flush debris from the water supply line before
connecting it to the dishwasher. Damage caused by improper installation is not
covered by the limited warranty.
•
WATER HARDNESS OF 3 GRAINS/US GAL - 0.83 IMP GAL - 5.3 MG/L or LESS
•
INSTALL A 1/2" OR LARGER SHUT-OFF VALVE IN THE WATER SUPPLY LINE AS CLOSE TO THE
DISHWASHER AS POSSIBLE FOR SERVICING.
•
WATER SUPPLY CONNECTION IS LOCATED UNDERNEATH THE DISHWASHER.
•
CONNECT A 1/2" NPT DRAIN LINE TO THE DWT DEVICE.
4
•
MINIMUM 1/2" NPT COLD WATER SUPPLY LINE.
•
MINIMUM INCOMING FLOW PRESSURE = 45 PSI/310.3
MINIMUM INCOMING
WATER TEMPERATURE
36°F/ 2°C
To prevent damage to the dishwasher supply valves, the installing
Fig. 6 - Mechanical DWT valve.
MAXIMUM INCOMING
PRESSURE
SUPPLY
60 PSI/414 kPa
kPa