VHR HOT WATER CONNECTION

HOT
WATER
CAUTION:
plumber must thoroughly flush debris from the water supply line before
connecting it to the dishwasher. Damage caused by improper installation is not
covered by the limited warranty.
BOOSTER
MINIMUM INCOMING
RISE °F
WATER TEMPERATURE
40°F
140°F/60°C
12kW
RISE
70°F
21kW
110°F/ 43°C
RISE
NO
180°F/ 82°C
BOOSTER
WATER HARDNESS OF 3 GRAINS/US GAL - 0.83 IMP GAL - 5.3 MG/L or LESS
WATER SUPPLY CONNECTION IS LOCATED AT THE TOP OF THE DISHWASHER.
INSTALL A 3/4" OR LARGER SHUT-OFF VALVE IN THE WATER SUPPLY LINE AS CLOSE TO
THE DISHWASHER AS POSSIBLE FOR SERVICING.
MINIMUM 3/4" NPT HOT WATER SUPPLY LINE.
OPERATING FLOWING PRESSURE = 20 PSI/138-152 kPa
PRV REQUIRED IF INCOMING PRESSURE EXCEEDS
60 PSI/413.7 kPa
To prevent damage to the dishwasher supply valves, the installing
MINIMUM INCOMING
PRESSURE
SUPPLY FLOWING
45 PSI/310 kPa
45 PSI/310 kPa
45 PSI/310 kPa
Fig. 6 - Heat recovery hot water connection.
PRESSURE
OPERATING FLOWING
20 PSI 138 kPa
20 PSI 138 kPa
20 PSI 138 kPa
3/4" NPT
Hot Water
Installation
7