Heat Recovery, Hr, Hot Water Connection - Champion 64 PRO Series Installation Manual

Two tank rack conveyor dishwasher
Table of Contents

Advertisement

HEAT RECOVERY, HR, HOT WATER CONNECTION

HOT
WATER
CAUTION:
plumber must thoroughly flush debris from the water supply line before
connecting it to the dishwasher. Damage caused by improper installation is not
covered by the limited warranty.
BOOSTER
MINIMUM INCOMING
RISE °F
WATER TEMPERATURE
40°F
140°F/60°C
12kW
RISE
70°F
21kW
110°F/ 43°C
RISE
NO
180°F/ 82°C
BOOSTER
WATER HARDNESS OF 3 GRAINS/US GAL - 0.83 IMP GAL - 5.3 MG/L or LESS
INSTALL A 3/4" NPT OR LARGER SHUT-OFF VALVE IN THE WATER SUPPLY LINE AS CLOSE TO
THE DISHWASHER FOR SERVICING.
WATER SUPPLY CONNECTION IS LOCATED AT REAR OF MACHINE AT THE UNLOAD END OF
THE MACHINE
3/4" NPT
Hot Water
Fig. 8 - Heat recovery Hot water connection.
MINIMUM 3/4" NPT HOT WATER SUPPLY LINE.
MINIMUM INCOMING FLOW PRESSURE = 30 PSI/206.8 kPa
PRV REQUIRED IF INCOMING PRESSURE EXCEEDS 60 PSI/413.7 kPa
To prevent damage to the dishwasher supply valves, the installing
MINIMUM
INCOMING FLOWING
30 PSI/206.8 kPa
30 PSI/206.8 kPa
30 PSI/206.8 kPa
PRESSURE
Installation
9