04. FIRST COMMISSIONING

01. Thoroughly clean the machine prior to start up (see chapter 06.01.).
02. Make sure that the machine and all electrical cables have no damage.
03. Have specialists verify, whether the machine may be operated using the available grid supply
voltage, and whether it is correctly connected.
04. Connect the machine to the compressed air system. The operating pressure at the filter valve
is 6 bar. (See chapter 08.06. Pneumatic connection)
In the case of deviations, the machine must NOT be started up!
Connect the machine to a grounded power socket only!
04. COMMISSIONING & WELDING

05. SWITCHING ON/OFF

DISPLAY
» SWITCHING ON
1
V
E
T
R
O
N
S
W
1
1
.
2
S
N
1
1
1
1
1
P
-
-
P D L
E A
3
R M
E
O
V
E
M
A
T
E
R
I
A
L
P D L
E A
4
P E
L
A
S
E
W
A
I
T
.
.
.
P 2
1 3
W
1
2
3
4
5
P
R G
O
R
A
M
N
A
M
E
» SWITCHING OFF
1
P
O
W
E
R
O
F
F
2
02/2021
28
VETRON 5064 Welding Machine
STEP
Switch ON the CONTROL by using the main switch
7
Press the pedal forward and remove any
material under the welding wheel
Machine initializes itself
5
Machine is ready for operation.
Before turning machine o , YOU HAVE TO RE-
MOVE THE WELDING WHEEL!
Switch OFF the CONTROL by using the main switch.
DESCRIPTION
Display for 5 seconds: SW1.17 = Software version
(can be di erent after update)
ID00042 = Identification number
(consecutive number)
The wheel travels into the starting situation.
P123
= The program number used last is
activated.
W12345 = Number of the installed wheel
Sonotrode could be destroyed
Remove the welding wheel to prevent it
from hitting the sonotrode.