Error Messages During Welding - VETRON 5064 Service Manual

Table of Contents

Advertisement

04. COMMISSIONING & WELDING

16. ERROR MESSAGES DURING WELDING

-1-2
DISPLAY
» ERROR MASSAGES
Pressure system can't
E2
initialize
Anvil sensor no
E3
response
E5 Memory full
EEPROM memory too
E7
small
Number of Parameters
E8
too high
E9 Head PCB no response
Auto gap processor
E10
error
E11 Stepper error
E13 Position read error
E14 Interval memory full
E15 No interval programmed Interval programm without interval setting
E16 Index overrun
E17 EEPROM PAR R/W error Head Base PCB damage
E19 Parameter default load
02/2021
42
VETRON 5064 Welding Machine
STEP
Stepper, sensor PCB, Cables
Magnet strip, gap, cables
Head Base memory full
Sytem error
Reserved parameter space overflow
Cable, PCB damaged
Check if sensor is ok
» Red-LED = Information that power is on
» Green-LED = Information that sensor is
correct adjusted and in correct position
Stepper driver malfunction
Stepper position read error
Maximum interval reached
Memory full
Some parameters loaded with full default value
SOLUTION
Check pressure mechanical system and sensor
PCB
Check magnet strip and its gap to encoder chip
on PCB
Delete unused programs
Call VETRON
Call VETRON
Check cables, call VETRON
» If green-LED is not lit, please adjust sensor
or change sensor
» Check if plug and socket of S1 is ok
» Make a Master Reset 1 (Basic Parameter
999). If it is not working, make a Master
Reset 2 (Basic Parameter 999)
NOTE: Before you make a Master Reset 2,
make a Backup for all programs in Data-
Manager
Restart, check cables
Check stepper motor and cable connections
Reduce interval steps
Add interval(s) to program
Call VETRON
Change PCB, call VETRON
Click to continue