Hisense Covidien HME2C26 User Manual page 27

Table of Contents

Advertisement

Operational Instructions and Function Adjustment
Note
If no signal is input in Single or Dual mode, the monitor enters the standby state.
In Dual mode, if a window has signal, the screen of the window without signal turns black.
INPUT1/INPUT2 is effective, both ▲UP and ▼DOWN are effective. The indicator
When
color is green. Other buttons are locked and their indicator color is white.
cannot be used to select the same signal source or restricted signal sources. The selection logic is
shown in the table below:
INPUT 1
DVI 1
DVI 2
SDI
VGA
YPbPr
Multi-window Display Mode Selection
In the power-on state, you can select the display mode PIP or PBP. Options are:
Option
Off
Large PIP
Medium PIP
Small PIP
Level PBP
Fill PBP
Adjustment Procedure
Press
PIP to call out the PIP/PBP menu.
Press ▲UP or ▼DOWN to select different options.
Press
PIP to exit the current menu.
Note
DVI 1
DVI 2
X
X
X
Definition
Only one window is displayed.
The height of the secondary window is 50% that of the
primary window.
The height of the secondary window is 40% that of the
primary window.
The height of the secondary window is 30% that of the
primary window.
The primary window is flush with the secondary window.
The primary and secondary windows fill half of the screen
respectively.
INPUT 2
SDI
X
X
17
INPUT1/INPUT2
VGA
YPbPr
X
X
X
X
Graphic