  • Page 2: Preface

    Preface Dear users, Hello. Thank you for purchasing Hisense LCD monitor, which will provide you with satisfying display effect. Read the User Guide thoroughly before using the LCD monitor and keep it properly for future reference. Hisense bears no responsibility for accidents caused by violating the safety precautions and instructions in this manual.
  • Page 3: Safety Information And Precautions

     It is recommended that you use the specified accessories of the LCD monitor, which can be used only with the spare parts and accessories that are manufactured or specified by Hisense.  It takes about 30 minutes for the electronic components of the LCD monitor to achieve stable performance.
  • Page 4 To avoid hazards, do not place the LCD monitor on a soft pad. If the LCD monitor will not be used for a long time, disconnect its power cable. The LCD monitor contains hazardous high voltage inside, so do not disassemble it by yourself. If the LCD monitor is abnormal, contact Hisense or an authorized distributor.
  • Page 5: Table Of Contents

    Contents Preface ..............................2 Safety Information and Precautions ....................3 Contents .............................. 1 Overview ............................. 2 Features ............................2 Technical Specifications ......................3 Accessories ..........................4 Installation ............................5 Front and Rear Views of the LCD Monitor ................. 5 Front View of the LCD Monitor and Buttons ................6 Rear View of the LCD Monitor and Input Ports ................
  • Page 6: Overview

    Overview Thank you for purchasing Hisense LCD monitor, which complies with the DICOM Part 14 standard and is applicable to DSA, MRI, DR, CR, CT, and PET medical imaging. It is intended for professionally trained medical staff and provides the image viewing and medical diagnostic functions.
  • Page 7: Technical Specifications

    Overview Technical Specifications Model HMD5G21S Name LCD monitor Size 21.3 inches (540 mm) Panel type Gray scale LCD panel (IPS) Resolution (H) 2560 x 2048 (V) pixel Display area (H) 422.4 x 337.9 (V) mm Pixel pitch (H) 0.165 x 0.165 (V) mm...
  • Page 8: Accessories

    The accessory list is for reference only. If any component is lost or damaged, promptly contact Hisense or the specified distributor. Keep the original package properly. If you need to return this product, be sure to use the original package. Do not place any heavy weight on top of the package during transportation.
  • Page 9: Installation

    Installation Front and Rear Views of the LCD Monitor Original packaging The monitor is lifted to the highest position Rotate 90° clockwise to change to vertical orientation Rear view of the LCD monitor in vertical orientation CAUTION  When adjusting the height of the monitor, hold the left and right sides of the monitor with both hands.
  • Page 10: Front View Of The Lcd Monitor And Buttons

    Installation Front View of the LCD Monitor and Buttons Note  For instructions on using the buttons, see the "Operational Instructions and Function Adjustment" section.
  • Page 11: Rear View Of The Lcd Monitor And Input Ports

    Installation Rear View of the LCD Monitor and Input Ports Port Function Power port Connected to the power adapter. Connected to a PC for LCD monitor debugging or parameter setting. Input: 5 V, 1 USB1 (uplink port) DP IN/DVI Connected to the digital output port on the graphics card of the PC. Connected to the input port of another monitor, with support for daisy chain DP OUT output.
  • Page 12: Hanging Arm Installation

    Installation Hanging Arm Installation Remove the base assembly to install the required hanging arm or base.  Follow the instructions in the User Guide when installing the hanging arm or base.  Before using the hanging bracket or base provided by another manufacturer, ensure that it meets the following requirements and complies with the VESA standard: - Screw hole spacing: 100 mm x 100 mm –...
  • Page 13: Cable Connection

    Installation Cable Connection The LCD monitor provides multiple connections to a PC and allows you to switch to any of the channels for display. The following figure shows the PC connection diagram. DVI port DP IN port DP OUT port Digital Digital Digital...
  • Page 14: Usb Connection

    Installation Use the DP OUT terminal to connect to another monitor as follows: Output the input signals of the DP IN channel to another monitor through the DP OUT channel to implement dual-screen independent display. The daisy chain must be supported by the graphics card. DP IN port DP IN port DP OUT port...
  • Page 15: Operational Instructions And Function Adjustment

    Operational Instructions and Function Adjustment Operational Instructions Operational Instructions  Buttons of the LCD monitor When the monitor is vertically placed, there are six adjustment buttons and one power button at the lower right side of the frame, and the functions are defined as follows: Button Function DICOM300, DICOM350, DICOM400, DICOM450, DICOM500, DICOM550,...
  • Page 16: Light Box

    Operational Instructions and Function Adjustment Procedure: Mode Press the button on the LCD monitor to go to the Mode screen. to select a display mode. In Custom mode, press ▲/▼ to adjust 2) Press backlight brightness. DICOM300/DICOM350/ DICOM400/DICOM450/DICOM500/DICOM550/DICOM600/DICOM6 50/DICOM700 mode, after you press the button, the system automatically switches to the DICOM mode.
  • Page 17: Menu Adjustment

    Operational Instructions and Function Adjustment Menu Adjustment Main Menu Display  In the power-on state, press to call out the User menu and press to close the menu.  The following table lists the configurable items of the menu. Main Menu First-level Menu Second-level Menu Remarks...
  • Page 18: Setting And Adjustment

    Operational Instructions and Function Adjustment Setting and Adjustment  Press on the monitor to call out the User menu.  Press ▲/▼ to select the main menu item you want to adjust or User menu Display Settings set, and press to go to the next menu.
  • Page 19 Operational Instructions and Function Adjustment Mode  Select the display mode to be adjusted. The following table lists the initial values of all modes. Mode Brightness (cd/m Gamma Value DICOM300 DICOM DICOM350 DICOM DICOM400 DICOM DICOM450 DICOM DICOM500 DICOM DIC0M550 DICOM DICOM600 DICOM...
  • Page 20 Operational Instructions and Function Adjustment Gamma  Set Gamma to adjust the Gamma curve displayed by an image. Options are DICOM, CT, MRI, DSA, DR, CR, MM, Gamma 1.8, Gamma 2.0, Gamma 2.2, Gamma 2.4, and Gamma 2.6. Note  This item can be adjusted only in Custom mode.
  • Page 21: User Menu - Power Saving Manager

    Operational Instructions and Function Adjustment User menu – Power Saving manager  In the power-on state, you can enable or disable the power indicator and ambient light sensor of the LCD monitor. Procedure: Power Saving manager Press the button on the LCD monitor to go to the User User menu menu.
  • Page 22: User Menu - Calibration Settings

    Operational Instructions and Function Adjustment User Menu – Calibration Settings  The Calibration Settings menu provides the Auto Calibration and Auto Validation items. User menu Calibration Settings Auto Calibration Procedure: Auto Validation Press the button on the LCD monitor to go to the User menu. Press ▲/▼...
  • Page 23: User Menu - Monitor Settings

    Menu Location Upper Left Press the button on the LCD monitor to go to the User menu. Language Chinese Hisense LOGO Press ▲/▼ to select the icon. Press to go to the Signal Input Auto Monitor Settings menu on the right.
  • Page 24 Operational Instructions and Function Adjustment seconds, and the power indicator lights on in orange.  While the LCD monitor is in sleep mode, the system automatically wakes up display when detecting an input signal. Monitor Info  Tap Monitor Info to view the basic monitor model, resolution, serial number, firmware version, product use duration, backlight use duration, and ambient light.
  • Page 25: Troubleshooting

    Troubleshooting Troubleshooting Before repair, check the following table to see if you can identify the cause of the fault. If the fault persists after you follow the instructions in the User Guide, you can consider repair. Fault Symptom Solution  Check whether the power plug is securely connected to the socket.
  • Page 26: Safety Statement

     Consult Hisense.  Use the power adapter and power cable provided by Hisense, and ensure that the LCD monitor is properly connected to ground.  Do not modify or retrofit the LCD monitor by yourself. Failure to comply with cause interference and damage to the LCD monitor.
  • Page 27: Environmental Protection Information

    Environmental Protection Information Environmental Protection Information  The LCD monitor meets the environmental protection requirements of the Administrative Measures for Limiting the Use of Hazardous Substances in Electrical and Electronic Products.  During its environmental-friendly service life, the LCD monitor does not cause leakage and precipitation of harmful substances and other problems affecting the health of users in the process of use, so it can be used safely.
  • Page 28: Maintenance Disclaimer

    User Guide but encounters equipment failure, parts damage, or monitor brightness not reaching the brightness value recommended in the User Guide, Hisense will repair or replace the product according to its own judgment.
  • Page 29: Appendix: List Of Terms

    Appendix: List of Terms  Digital Imaging and Communications in Medicine (DICOM) DICOM was jointly developed by American College of radiology (ACR) and National Electrical Manufacturers Association (NEMA). DICOM-compatible device connections can transmit medical images and data. DICOM Part 14 specifies the standard display functions of medical gray scale images.