Advertisement

Quick Links

RSAG2.025.6801SS B Version
Hisense website: www.hisense.com
User Guide
Read the User Guide thoroughly before
using Hisense LCD monitor and keep it
properly for future reference.
HMD4C27S

Advertisement

Table of Contents
loading

Summary of Contents for Hisense HMD4C27S

  • Page 1 HMD4C27S User Guide Read the User Guide thoroughly before using Hisense LCD monitor and keep it properly for future reference. RSAG2.025.6801SS B Version Hisense website: www.hisense.com...
  • Page 2: Preface

    Preface Dear users, Hello. Thank you for purchasing Hisense LCD monitor, which will provide you with satisfying display effect. Read the User Guide thoroughly before using the LCD monitor and keep it properly for future reference. Hisense bears no responsibility for accidents caused by violating the safety precautions and instructions in this manual.
  • Page 3: Safety Information And Precautions

     It is recommended that you use the specified accessories of the LCD monitor, which can be used only with the spare parts and accessories that are manufactured or specified by Hisense.  It takes about 30 minutes for the electronic components of the LCD monitor to achieve stable performance.
  • Page 4 To avoid hazards, do not place the LCD monitor on a soft pad. If the LCD monitor will not be used for a long time, disconnect its power cable. The LCD monitor contains hazardous high voltage inside, so do not disassemble it by yourself. If the LCD monitor is abnormal, contact Hisense or an authorized distributor.
  • Page 5: Table Of Contents

    Contents Preface ..............................I Safety Information and Precautions ....................II Contents .............................. 1 Overview ............................. 2 Features ............................2 Technical Specifications ......................3 Accessories ..........................4 Installation ............................5 Front and Rear Views of the LCD Monitor ................. 5 Front View of the LCD Monitor and Buttons ................6 Rear View of the LCD Monitor and Input Ports ................
  • Page 6: Overview

    Overview Thank you for choosing Hisense LCD. This product conforms to the DICOM Part 14 standard and is suitable for medical images such as DSA, MRI, DR, CR, CT, and PET. It provides image browsing and medical diagnosis functions for trained medical personnel.
  • Page 7: Technical Specifications

    Overview Technical Specifications Model HMD4C27S Name LCD monitor Size 27 inches Panel type Color LCD panel (IPS) Resolution 2560x1440 Display area (H) 596.74 x (V) 335.66 (mm) LCD monitor 233.1 x 233.1 (μm) Pixel pitch panel Contrast 1000:1 (typical) Horizontal: 178°; vertical: 178° (CR ≥ 10) (typical)
  • Page 8: Accessories

    The accessory list is for reference only. If any component is lost or damaged, promptly contact Hisense or the specified distributor. Keep the original package properly. If you need to return this product, be sure to use the original package. Do not place any heavy weight on top of the package during transportation.
  • Page 9: Installation

    Installation Front and Rear Views of the LCD Monitor Original packaging The monitor is lifted to the highest position CAUTION  When adjusting the height of the monitor, hold the left and right sides of the monitor with both hands. Do not put your hands directly under the monitor to avoid pinching your hands when the monitor reaches the lowest level.
  • Page 10: Front View Of The Lcd Monitor And Buttons

    Installation Front View of the LCD Monitor and Buttons Human sensor Power indicator Button Function MENU/selection button The main menu is displayed when no menu option is available. OK is Menu displayed when a menu option is available. ▲ Upward When no UI is displayed, the Upward button is used to call out the one-click highlight function, and the Downward button is used to ▼...
  • Page 11: Rear View Of The Lcd Monitor And Input Ports

    Installation  When the monitor is in standby mode, you can press any button to awake it.  If no operation is performed, the shortcut operation page automatically disappears in 3s and the Settings menu automatically disappears in 15s.  If you do not need to use the monitor for a long time, press Power to power off the monitor or remove the power plug to save the energy.
  • Page 12: Hanging Arm Installation

    Installation Hanging Arm Installation Remove the base assembly to install the required hanging arm or base.  Follow the instructions in the User Guide when installing the hanging arm or base.  Before using the hanging bracket or base provided by another manufacturer, ensure that it meets the following requirements and complies with the VESA standard: –...
  • Page 13: Pc Connection

    Installation PC Connection 1. Connect the signal cable Check the shape and mark of the signal connection port, connect the signal connection port to a PC signal cable, and tighten the screws of the connector to fix the connection. The following takes the DVI and DP signal cables as an example: DVI port DP port Digital...
  • Page 14: Operational Instructions And Function Adjustment

    Operational Instructions and Function Adjustment Menu Adjustment Main Menu Display  In the power-on state, press to call out the User menu and press to close the menu.  The following table lists the configurable items of the menu. First-level Main Menu Second-level Menu Remarks Menu...
  • Page 15 Operational Instructions and Function Adjustment First-level Main Menu Second-level Menu Remarks Menu Settings Contrast 0-100 6500K/7500K/8500K/9300K/Original/Eye Color temperature Care/Custom Gamma DICOM/CT/MRI/DSA/DR/1.8/2.0/2.2/2.4/2.6 Execution Auto Calibration Result Calibration Settings Execution Auto-validation Result Language Chinese and English Menu Settings Menu Location Bottom Left, Bottom Right, and Center Menu Transparency High/Medium/Low Power High...
  • Page 16: Setting And Adjustment

    Operational Instructions and Function Adjustment Setting and Adjustment  Press on the monitor to call out the User menu. Press ▲ or ▼ to select the main menu item to be adjusted and set  Settings Display Mode and press to enter the lower-level menu.
  • Page 17: User Menu-Image Settings

    Operational Instructions and Function Adjustment User Menu-Image Settings  You can set different signal sources for each window in different display modes. Procedure: 1) In the User menu, press ▲ or ▼ to select Image Settings and then press to enter the Image Settings menu. 2) Press ▲...
  • Page 18: User Menu-System Settings

    Operational Instructions and Function Adjustment result. 5) Press to return to the User menu. Note: 1) This function is available only in Single mode. 2) This function is available 30 minutes after the system is powered User Menu-System Settings  In the power-on state, you can set other functions for the monitor.
  • Page 19: Troubleshooting

    Troubleshooting Troubleshooting Before repair, check the following table to see if you can identify the cause of the fault. If the fault persists after you follow the instructions in the User Guide, you can consider repair. Fault Symptom Solution  Check whether the power plug is securely connected to the socket.
  • Page 20: Safety Statement

     Consult Hisense.  Use the power adapter and power cable provided by Hisense, and ensure that the LCD monitor is properly connected to ground.  Do not modify or retrofit the LCD monitor by yourself. Failure to comply with cause interference and damage to the LCD monitor.
  • Page 21: Environmental Protection Information

    Environmental Protection Information Environmental Protection Information  The LCD monitor meets the environmental protection requirements of the Administrative Measures for Limiting the Use of Hazardous Substances in Electrical and Electronic Products.  During its environmental-friendly service life, the LCD monitor does not cause leakage and precipitation of harmful substances and other problems affecting the health of users in the process of use, so it can be used safely.
  • Page 22: Maintenance Disclaimer

    User Guide but encounters equipment failure, parts damage, or monitor brightness not reaching the brightness value recommended in the User Guide, Hisense will repair or replace the product according to its own judgment.
  • Page 23: Appendix: List Of Terms

    Appendix: List of Terms  Digital Imaging and Communications in Medicine (DICOM) DICOM was jointly developed by American College of Radiology (ACR) and National Electrical Manufacturers Association (NEMA). DICOM-compatible device connections can transmit medical images and data. DICOM Part 14 specifies the standard display functions of medical gray scale images.
  • Page 24 Qingdao Hisense Medical Equipment Co., Ltd. Address: North, 3F, Outsourcing Center of Software Park, No. 169, Songling Road, Laoshan District, Qingdao, P.R.China Hisense national customer service hotline: 4009940707 Hisense Group service supervision email: haixinfuwu@hisense.com...

Table of Contents