Advertisement

Quick Links

RSAG2.025.7172SS B Version
Hisense website: www.hisense.com
User Guide
Read the User Guide thoroughly before
using Hisense LCD monitor and keep it
properly for future reference.
HMD6C30S

Advertisement

Table of Contents
loading

Summary of Contents for Hisense HMD6C30S

  • Page 1 HMD6C30S User Guide Read the User Guide thoroughly before using Hisense LCD monitor and keep it properly for future reference. RSAG2.025.7172SS B Version Hisense website: www.hisense.com...
  • Page 2: Preface

    Read the User Guide thoroughly before using the LCD monitor and keep it properly for future reference. Hisense shall not be liable for any accidents arising from violations of the safety precautions and use instructions of the User Guide.
  • Page 3: Safety Information And Precautions

     It is recommended that you use the specified accessories of the LCD monitor, which can be used only with the spare parts and accessories that are manufactured or specified by Hisense.  It takes about 30 minutes for the electronic components of the LCD monitor to achieve stable performance.
  • Page 4 To avoid hazards, do not place the LCD monitor on a soft pad. If the LCD monitor will not be used for a long time, disconnect its power cable. The LCD monitor contains hazardous high voltage inside, so do not disassemble it by yourself. If the LCD monitor is abnormal, contact Hisense or an authorized distributor.
  • Page 5: Table Of Contents

    Contents Preface ..............................I Safety Information and Precautions ....................II Contents .............................. 1 Overview ............................. 2 Features ............................2 Technical Specifications ......................3 Accessories ..........................4 Installation ............................5 Front and Rear Views of the LCD Monitor ................. 5 Front View of the LCD Monitor and Buttons ................6 Rear View of the LCD Monitor and Input Ports ................
  • Page 6: Overview

    Overview Thank you for purchasing Hisense LCD monitor, which complies with the DICOM Part 14 standard and is applicable to DSA, MRI, DR, CR, CT, and PET medical imaging. It is intended for professionally trained medical staff and provides the image viewing and medical diagnostic functions.
  • Page 7: Technical Specifications

    Overview Technical Specifications Model HMD6C30S LCD monitor Name Size 30 inches Panel type Color LCD panel (IPS) Resolution 3280x2048 Display area (H) 645.504 x (V) 403.046 (mm) Pixel pitch 0.197 (H) x 0.197 (V) (mm) LCD monitor Contrast 950:1 (typ.) panel Horizontal: 170°...
  • Page 8: Accessories

    The accessory list is for reference only. If any component is lost or damaged, promptly contact Hisense or the specified distributor. Keep the original package properly. If you need to return this product, be sure to use the original package. Do not place any heavy weight on top of the package during transportation.
  • Page 9: Installation

    Installation Front and Rear Views of the LCD Monitor Original packaging The monitor is lifted to the highest position CAUTION  When adjusting the height of the monitor, hold the left and right sides of the monitor with both hands. Do not put your hands directly under the monitor to avoid pinching your hands when the monitor reaches the lowest level.
  • Page 10: Front View Of The Lcd Monitor And Buttons

    Installation Front View of the LCD Monitor and Buttons Human sensor Power indicator Button Function MENU/selection button The main menu is displayed when no menu option is available. OK is displayed Menu when a menu option is available. ▲ Upward When no UI is displayed, the Upward button is used to call out the one-click highlight function, and the Downward button is used to adjust the backlight ▼...
  • Page 11: Rear View Of The Lcd Monitor And Input Ports

    Installation  When the monitor is in standby mode, you can press any button to awake it.  If no operation is performed, the shortcut operation page automatically disappears in 3s and the Settings menu automatically disappears in 15s.  If you do not need to use the monitor for a long time, press Power to power off the monitor or remove the power plug to save the energy.
  • Page 12: Hanging Arm Installation

    Installation Hanging Arm Installation Remove the base assembly to install the required hanging arm or base.  Follow the instructions in the User Guide when installing the hanging arm or base.  Before using the hanging bracket or base provided by another manufacturer, ensure that it meets the following requirements and complies with the VESA standard: - Screw hole spacing: 100 mm x 100 mm –...
  • Page 13: Pc Connection

    Installation PC Connection 1. Connect the signal cable Check the shape and mark of the signal connection port, connect the signal connection port to a PC signal cable, and tighten the screws of the connector to fix the connection. The following takes the DVI and DP signal cables as an example: DVI port DP port...
  • Page 14: Operational Instructions And Function Adjustment

    Operational Instructions and Function Adjustment Menu Adjustment Main Menu Display  In the power-on state, press to call out the User menu and press to close the menu.  The following table lists the configurable items of the menu. Main Menu First-level Menu Second-level Menu Remarks...
  • Page 15: Setting And Adjustment

    Operational Instructions and Function Adjustment Main Menu First-level Menu Second-level Menu Remarks Execution Auto Calibration This function is available only in Single mode. Result Calibration This function is available in 30 minutes after Settings Execution power-on. Auto validation Result Language Chinese and English Menu Settings Menu Location...
  • Page 16: User Menu-Signal Input

    Operational Instructions and Function Adjustment Procedure: 1) In the User menu, press ▲ or ▼, select Display Mode, and then press Display Mode to enter the Display Mode sub-menu. Single 2) Press ▲ or ▼ to select the item to be adjusted and then press .
  • Page 17: User Menu-Calibration Settings

    Operational Instructions and Function Adjustment 6) As for the settings of the Backlight menu, see the description below. 7) In the Image Enhancing menu, six enhancing modes are available. The default value is Off. 8) In the Advanced Settings menu, you can set Brightness, Contrast, Color Temp., and Gamma.
  • Page 18: User Menu-System Settings

    Operational Instructions and Function Adjustment User Menu-System Settings  In the power-on state, you can set other functions for the monitor. Procedure: 1) In the User menu, press ▲ or ▼ to select System Settings and then press to enter the System Settings menu. 2) Press ▲...
  • Page 19: Troubleshooting

    Troubleshooting Troubleshooting Before repair, check the following table to see if you can identify the cause of the fault. If the fault persists after you follow the instructions in the User Guide, you can consider repair. Fault Symptom Solution  Check whether the power plug is securely connected to the socket.
  • Page 20: Safety Statement

     Consult Hisense.  Use the power adapter and power cable provided by Hisense, and ensure that the LCD monitor is properly connected to ground.  Do not modify or retrofit the LCD monitor by yourself. Failure to comply with cause interference and damage to the LCD monitor.
  • Page 21: Environmental Protection Information

    Environmental Protection Information Environmental Protection Information  The LCD monitor meets the environmental protection requirements of the Administrative Measures for Limiting the Use of Hazardous Substances in Electrical and Electronic Products.  During its environmental-friendly service life, the LCD monitor does not cause leakage and precipitation of harmful substances and other problems affecting the health of users in the process of use, so it can be used safely.
  • Page 22: Maintenance Disclaimer

    User Guide but encounters equipment failure, parts damage, or monitor brightness not reaching the brightness value recommended in the User Guide, Hisense will repair or replace the product according to its own judgment.
  • Page 23: Appendix: List Of Terms

    Appendix: List of Terms  Digital Imaging and Communications in Medicine (DICOM) DICOM was jointly developed by American College of Radiology (ACR) and National Electrical Manufacturers Association (NEMA). DICOM-compatible device connections can transmit medical images and data. DICOM Part 14 specifies the standard display functions of medical gray scale images.
  • Page 24 Qingdao Hisense Medical Equipment Co., Ltd. Address: North, 3F, Outsourcing Center of Software Park, No. 169, Songling Road, Laoshan District, Qingdao, P.R.China Hisense national customer service hotline: 4009940707 Hisense Group service supervision email: haixinfuwu@hisense.com...

Table of Contents