Connection Diagram Options E6 And E12 - E+E Elektronik EE310 Operation Manual

Humidity/temperature transmitter
Hide thumbs Also See for EE310:
Table of Contents

Advertisement

Model
EE310 with option E5
Model
EE310 with option E5
Tab. 3
Cable gland
power supply +
analogue output
Model
EE310 with option
E5 and J3
Tab. 4
M12 connector Modbus RTU
M16x1.5
3.2.4

Connection diagram Options E6 and E12

Modbus RTU
Option E6
Modbus RTU power supply +
analogue output
Option E12
power supply +
Modbus RTU
analogue output
Fig. 10
Plug option E6 and E12 (front connector view)
Operating instructions for EE310 Humidity / Temperature Transmitter
Supply Input
Voltage/Frequency
Indoor use:
12 to 30Vac, 50/60Hz (Class 2 supply)
8-35Vdc (LPS)
Outputs
Type
Out 1
GND Output
Out 2
OUT 2
GND
4
3
5
1
2
OUT 1
V+
Outputs
GND RS485
Type
(shielded)
n.c.
RS485 A
Modbus RTU
3
4
5
2
1
n.c.
RS485 B
(=D-)
GND RS485
(shielded)
n.c.
RS485 A
3
4
5
2
1
n.c.
RS485 B
(=D-)
Modbus RTU
GND RS485
(shielded)
n.c.
RS485 A
3
4
5
2
1
n.c.
RS485 B
(=D-)
Modbus RTU
Ratings
0-1V
0-5V
0-10V
0-20mA
4-20mA
(SELV Limited Energy source)
0-1V
0-5V
0-10V
0-20mA
4-20mA
(SELV Limited Energy source)
Ratings
0-5V
(SELV Limited Energy source)
(=D+)
GND Output
OUT 2
4
3
(=D+)
5
1
2
V+
Power supply + analogue output
GND Output
OUT 2
4
3
(=D+)
5
1
2
n.c.
Analogue output
Terminals
Plug pin
V+ (1) –
GND (2)
Terminals
Plug pin
Out 1 (4) –
GND (3)
Out 2 (5) –
GND (3)
Terminals
RS485 A (=D+) (2) –
RS485 B (=D-) (4) –
GND RS485 (5)
GND
OUT 1
n.c.
OUT 1
11