11 Ordering Guide

without
Approval
UL-Approval
wall mounting
duct mounting
Type
remote probe up to 180 °C (356 °F)
remote probe up to 180 °C (356 °F) and 100 bar (1435 psi)
remote probe up to 180 °C (356 °F)and 20 bar (300 psi)
plastic - PTFE membrane (up to 180 °C / 356 °F)
plastic - metal grid (up to 120 °C / 248 °F)
stainless steel sintered
PTFE
Filter
stainless steel - metal grid (up to 180 °C / 356 °F)
H
O
2
oil
oil (short)
0.5 m (1.64 ft)
1 m (3.3 ft)
Cable length
2 m (6.6 ft)
5 m (16.4 ft)
(incl. probe length)
10 m (32.8 ft)
20 m (65.6 ft)
50 mm (2")
65 mm (2.55")
100 mm (3.9")
200 mm (7.9")
Probe length
300 mm (11.7")
400 mm (15.8")
600 mm (23.6")
800 mm (31.5")
1000 mm (39.4")
without probe fitting
1/2" ISO - cut in fitting; 12 mm (0.47")
1/2" weld - cut in fitting; 12 mm (0.47")
Process connection
1/2" NPT - cut in fitting; 12 mm (0.47")
1/2" ISO - cut in fitting; 13 mm (0.51")
1/2" weld - cut in fitting; 13 mm (0.51")
1/2" NPT - cut in fitting; 13 mm (0.51")
cable glands
1 plug for power supply and outputs
1 cable gland / 1 plug for Modbus RTU
Electrical connection
2 plugs for power supply / outputs and for Modbus RTU
1)
3 plugs for power supply / outputs and Modbus RTU
conduit fitting
liquid-tight 1/2" conduit fitting
TFT colour display with integrated data logger
Modbus RTU
E+E sensor coating
alarm outputs
Optional features
alarm outputs
integrated power supply 100...240 V AC, 50/60 Hz
integrated power supply 100...240 V AC, 50/60 Hz
liquid-tight 1/2" conduit fitting
relative humidity RH
Output 1
other measurand
0-1 V
0-5 V
Output Signal 1
0-10 V
0-20 mA
4-20 mA
0
Scaling 1 low
value
100
Scaling 1 high
value
temperature T
Output 2
temperature T
other measurand
0-1 V
0-5 V
Output Signal 2
0-10 V
0-20 mA
4-20 mA
Scaling 2 low
value
Scaling 2 high
value
1) Plug options E5 / E6 / E12 only in combination with Modbus RTU option J3.
2) Factory setup: the display shows the measurands selected for output 1 and output 2
Default language English, other languages selectable in display menu.
3) Alarm output with cable glands

11.1 Measurand Code

relative humidity
Temperature
dew point Td
frost point Tf
mixing ratio r
Operating instructions for EE310 Humidity / Temperature Transmitter
2
3) 4)
liquid-tight 1/2" conduit fitting
4) 6)
[%]
(xx see Measurand Code below)
[°C]
[°F]
(xx see Measurand Code below)
MAxx / MBxx
10
%
°C
1
°F
2
°C
52
°F
53
°C
65
°F
66
60
g/kg
gr/lb
61
T1
8)
2)
4) 5)
4) 7)
4) Combination of alarm output and integrated power supply is not possible
5) Integrated power supply includes 2 plugs for power supply and outputs
6) Alarm output with two 1/2" liguid-tight conduit fittings
7) Integrated power supply with two 1/2" liquid-tight conduit fittings
absolute humidity dv
wet bulb temperature Tw
water vapour partial pressure e
specific enthalpy h
EE310
no code
AP1
T2
T5
T8
F2
F3
no code
F5
F9
F12
F13
F16
K0.5
K0.5
K1
K1
no code
no code
K5
K5
K10
K10
K20
K20
L50
L65
L65
L100
L100
L100
no code
no code
no code
L300
L300
L300
L400
L400
L400
L600
L600
L600
L800
L800
L800
L1000
L1000
L1000
PA20
PA21
PA22
no code
E4
E5
E6
E12
E23
E24
D2
J3
C1
AM2
AM6
AM3
AM5
no code
MAxx
GA1
GA2
GA3
GA5
GA6
no code
SALvalue
no code
SAHvalue
no code
MB2
MBxx
GB1
GB2
GB3
GB5
GB6
SBLvalue
SBHvalue
MAxx / MBxx
g/m³
gr/ft³
°C
°F
mbar
psi
kJ/kg
BTU/lb
T10
K0.5
K1
no code
K5
K10
K20
L50
L65
L100
no code
L300
L400
L600
L800
L1000
no code
PA20
PA21
PA22
PA23
PA24
PA25
56
57
54
55
50
51
62
64
43