E+E Elektronik EE310 Operation Manual page 17

Humidity/temperature transmitter
Hide thumbs Also See for EE310:
Table of Contents

Advertisement

8 - 35 V DC
12 - 30 V AC
V
mA
V
mA
Model
EE310 with option AM2
Model
EE310 with option AM2
Model
EE310 with option AM3
and J3
Operating instructions for EE310 Humidity / Temperature Transmitter
Wire size:
30-16AWG
Type:
CU
V+
1
Supply
GND
2
GND
3
Analogue outputs
OUT 1
4
OUT 2
5
GND RS485
6
Modbus RTU
RS485 A (=D+)
7
(galvanically isolated)
RS485 B (=D-)
8
12 to 30Vac, 50/60Hz (Class 2 supply)
Type
Out 1
Out 2
Type
Modbus RTU
Terminal torque
USA:
6 Lb In.
CANADA:
0.7 Nm
Supply Input
Voltage/Frequency
8-35Vdc (LPS)
Outputs
Ratings
0-1V
0-5V
0-10V
0-20mA
4-20mA
(SELV Limited Energy source)
0-1V
0-5V
0-10V
0-20mA
4-20mA
(SELV Limited Energy source)
Ratings
0-5V
(SELV Limited Energy source)
Terminals
V+ (1) –
GND (2)
Terminals
Out 1 (4) –
GND (3)
Out 2 (5) –
GND (3)
Terminals
RS485 A (=D+) (7) –
RS485 B (=D-) (8) –
GND RS485 (6)
17

Advertisement

Table of Contents
loading