GevSCPHostPort
GevSCPSFireTestPacket
True, False
GevSCPSDoNotFragment
True, False
GevSCPSPacketSize (B)
576〜16366
GevSCPD
0〜4294967295
GevSCDA
GevSCSP
Item
p) PulseGenerator
ClockPreScaler
1〜4096
PulseGeneratorClock (MHz)
0.0181274〜74.25
PulseGeneratorSelector
PulseGenerator0,
PulseGenerator1,
PulseGenerator2,
PulseGenerator3
PulseGeneratorLengthValue
1〜1048575
PulseGeneratorLength (ms)
PulseGeneratorFrequency (Hz)
PulseGeneratorClock (MHz) ÷
1048575 x 1000000 〜
PulseGeneratorClock (MHz) x
1000000
PulseGeneratorStartPointValue
0〜1048575
PulseGeneratorStartPoint (ms)
0〜42949.6
PulseGeneratorEndPointValue
1 〜 1048575
PulseGeneratorEndPoint (ms)
0〜42949.6
PulseGeneratorPulseWidth (ms)
PulseGeneratorRepeatCount
0 〜 255
PulseGeneratorClearActivation
Off,
LevelHigh,
LevelLow,
RisingEdge,
FallingEdge
PulseGeneratorClearSource
Exposure Active,
LVAL,
Pulse Generator[0 - 3],
UserOutput0, UserOutput1,
UserOutput2, UserOutput3,
Line4 TTL In 1,
Line5 Opt IN 1,
Line10 TTL In 2,
Line13 TTL In 3,
Logic Block 0, Logic Block 1,
Encoder Trigger
PulseGeneratorClearSyncMode
AsyncMode, SyncMode
False
False
1476
0
Setting range
Default value
165
0.45
PulseGenerator0
30000
0
0
15000
0.15
0.15
0
Off
Low
AsyncMode
— 55 —
Controls the port of the selected channel to which a GVSP transmitter must send data stream or
the port from which a GVSP receiver may receive data stream. Setting this value to 0 closes the
stream channel.
Sends a test packet. When this feature is set, the device will fire one test packet.
The state of this feature is copied into the "do not fragment" bit of IP header of each stream
packet. It can be used by the application to prevent IP fragmentation of packets on the stream
channel.
Set the packet size.
Controls the delay (in GEV timestamp counter unit) to insert between each packet for this
stream channel.
Controls the destination IP address of the selected stream channel to which a GVSP transmitter
must send data stream or the destination IP address from which a GVSP receiver may receive
data stream.
Indicates the source port of the stream channel.
Description
Configure pulse generator settings.
Set the division value for the prescaler (12 bit) using PixelClock as the base
clock.
Set the clock used for the pulse generator.
This value is calculated using the [ClockPreScaler] value as a base.
Select the pulse generator.
Set the maximum count-up value as a clock count.
Set the maximum count-up value in milliseconds.
This value is calculated using the [PulseGeneratorLength] value as a base.
The setting range varies depending on the [ClockPreScaler] value.
Set the maximum count-up value as a frequency.
This value is calculated using the
[PulseGeneratorLength] value as a base.
Set the start point of the High interval as a clock count. When the counter
reaches this value, the output will be 1.
Set the start point of the High interval in milliseconds.
When the counter reaches this value, the output will be 1.
The setting range varies depending on the [ClockPreScaler] value.
Set the start point of the Low interval as a clock count. When the counter
reaches this value, the output will be 0.
Set the start point of the Low interval in milliseconds.
When the counter reaches this value, the output will be 0.
The setting range varies depending on the [ClockPreScaler] value.
Display the High interval width of the pulse in milliseconds.
The duration between the Start Point and End Point is calculated. The setting
range varies depending on the [ClockPreScaler] value.
Set the repeat count for the counter. When this is set to [0], a free counter is
enabled with no repeat limit.
Set the clear signal condition for the count clear input of the pulse generator.
Select the count clear input signal source.
Select the sync mode for the count clear input signal.