Item
g) Digital I/O control
Line Selector
Line1 TTL Out 1,
Line4 TTL In 1
Line5 Opt In 1,
Line8 TTL Out 2,
Line9 TTL Out 3,
Line10 TTL In 2,
Line12 TTL Out 4,
Line13 TTL In 3
Line Mode
Input, Output
Line Inverter
True, False
Line Status
True, False
Line Source
Acquisition Active,
Frame Active,
Exposure Active,
LVAL,
Pulse Generator 0,
Pulse Generator 1,
Pulse Generator 2,
Pulse Generator 3,
User Output 0,
User Output 1,
User Output 2,
User Output 3,
Line4 TTL In 1,
Line5 Opt IN 1,
Line10 TTL In 2,
Line13 TTL In 3,
Logic Block 0,
Logic Block 1,
Encoder Trigger,
Encoder Direction
Line Format
NoConnect,
TTL,
OptoCoupled
InternalSignal
LineStatusAll
OptInFilterSelector (ns)
0 〜 1000000 step 100
UserOutputSelector
UserOutput0
UserOutput1
UserOutput2
UserOutput3
UserOutputValue
True, False
Setting range
Default value
False
Off
UserOutput0
False
— 48 —
Description
Configure settings for digital input/output.
Select the input/output to configure.
Display the input/output status (whether it is input or output).
Enable/disable polarity inversion for the selected input signal or output
signal.
Display the status of the input signal or output signal (True: High, False:
Low).
Select the line source signal for the item selected in [Line Selector].
Display the signal format.
Display the input/output signal status. The state is shown with 16 bits. Bit
assignments are as follows.
bit0:Line1
 bit1:Unused (fixed 0)
 bit2:Unused (fixed 0)
 bit3:Line4
 bit4:Line5
 bit5:Unused (fixed 0)
 bit6:Unused (fixed 0)
 bit7:Line8
 bit8:Line9
 bit9:Line10
 bit10:Unused (fixed 0)
 bit11:Line12
 bit12:Line13
 bit13-31:Unused (fixed 0)
Remove noise from the OptIn input signal of Digital I/O.
Set the UserOutput signal.
Set the value for the UserOutput selected in [UserOutputSelector].