■ Internal camera blocks
Counter0
Line Trigger
Counter1
Line Start
Counter2
Exposure Start
Counter5
Frame Transfer End
■ To use the counter function
Configure the settings as follows.
Six counters are available. Specify a counter (Counter0 to Counter5), and configure the
settings.
Item
Counter 0 ~ 5
CounterEventSource
CounterEventActivation
Event detection
Event detection
Event detection
At event occurrence or count up
Event detection
At event occurrence or count up
Counter reset
Internal MCU of camera
Setting value /
selectable range
Counter 0 ~ 5
Counter0
Off, Line Trigger
Counter1
Off, Line Start
Counter2
Off, Exposure Start
Counter3
Off, Frame Trigger
Counter4
Off, Frame Start
Counter5
Off, Frame Transfer End
Counter0 Rising Edge
Counter1 Rising Edge
Counter2 Rising Edge
Counter3 Rising Edge
Counter4 Rising Edge
Counter5 Falling Edge
— 36 —
Counter
At event occurrence or count up
Counter
At event occurrence or count up
Counter
Counter
Read requested counter value
Select the counter.
Select the counter event signal
for which to read the count
value.
When set to Off, the counter
operation will stop (but will not
be reset).
Specify timing at which to count.
(This setting is fixed.)