Crestron CNX-DVP4
Operations Guide – DOC. 8170A
System Setup Menu

Interface Menu

The CNX-DVP4 communicates with a control system to activate other controls or to
display feedback from components within the system. The INTERFACE MENU
(refer to the following graphic) allows you to set the correct Cresnet ID to
communicate with a control system or other Cresnet device. The INTERFACE
MENU also allows you to select Master, Ethernet slave mode, or Cresnet Slave
mode. Use Master mode when you want the CNX-DVP4 to operate as a control
system. Use the Slave mode when you want a control system to operate and control
the CNX-DVP4 via Cresnet or Ethernet.
The CRESNET ID is a two-digit hexadecimal number. This number can range from
02 to FE and must correspond to the NET ID set in the SIMPL Windows program of
the Cresnet system. Matching IDs between the CNX-DVP4 and SIMPL Windows
program is required if data is to be successfully transferred. NET ID is factory set to
54 in Cresnet slave mode. Selecting Master sets and locks the NET ID to 02.
• To set the Cresnet Slave mode, set the Cresnet ID to a number from 03 to FE.
• To set the Master mode, set the Cresnet ID to 02.
• To set the Ethernet (ESLAVE) mode, set the ID to 02 and setup the IP table.
• To remove the ESLAVE mode and return to the Master mode and remove the
IP table.
Digital Video Processor
Digital Video Processor: CNX- DVP4 • 25