YASKAWA Smart Series Application Note page 28

Robotiq 2-finger gripper
Hide thumbs Also See for Smart Series:
Table of Contents

Advertisement

Depending on the controller's configuration, the 5 digit I/O value for some entries may not be initialized.
This is indicated by "# - - - - -". {Select} one of these values to initialize all entries using {INIT}. This will
then allow the user to {MODIFY} the entry as shown above. See the process below for entry
initialization.
Press {ENTER} to bring up a similar page for the External Output Allocation once the External Input
Allocation is finalized.
External Outputs have a similar format shown below:
To change the location of the Output mapping, only the middle three numbers (defining the I/O Group
Number) should be changed. This will define the Output Group Number where the associated Outputs
will map. The table below shows a few example mappings and where they will land on YRC1000 vs.
YRC1000micro (output values are offset by 2 on the YRC1000).
External
Output #
30070
30310
31500
YRC1000
YRC1000
Group #
Individual #'s
5
33 to 40
29
225 to 232
148
1177 to 1184
YRC1000micro
YRC1000micro
Group #
Individual #'s
7
49 to 56
31
241 to 248
150
1193 to 1200
Page | 28