IntelliFlo VF Pump Settings

Pump Type
Filt. Circuit
Flows
Filtering
Priming
Backwash
Vacuum
Status
Pump #1
1/8
GPM : 30
Circuit:
[ AUX 1
]
Pump #1
1/8
GPM : 30
Circuit:
[ AUX 1
]
Pump Filtering
Size
: 1500
Turns : 2
Man Filt: 0
Pump Priming
Max Flow : 55
Max Time : 5
Sys time
: 0
Programming EasyTouch: IntelliFlo
TO CHANGE THE PUMP TYPE: Press the Right button to Select Pump Type.
Press the Up/Down button and select Y, then press the Right button. Press the
Up/Down button to change the pump type to VS or VF. Press MENU to save and
return to the selected pump's settings.
FILT. CIRCUIT: Press Down button, Choose FILT > CIRCUIT. Press Up/Down
button to select the pool filter circuit: NONE, SPA, POOL, AUX 1-7 (ET8), AUX 1-3
(ET4) and FEATURE 1-8. Press MENU to save.
VF FLOWS: Press Down button: Choose Flows. Press Right button: Access the
IntelliFlo VF flow settings. Press the Up/Down buttons to set GPM (15-130).
Press Right button to CIRCUIT for circuit 1 of 8. Assign the circuit: NONE, SPA,
POOL, AUX 1-7 (ET8), AUX 1-3 (ET4), FEATURE 1-8, SOLAR (if enabled in the
Solar menu) or AUX EXTRA (only if Solar is not selected, see page 25 and 42),
HEATER, POOL HEATER, SPA HEATER, FREEZE, and HI_SPEED. AUX EXTRA
is only available if the Solar output (J17) plug on the EasyTouch motherboard
is not being used for solar equipment. After circuit selection is finished, press
Right button: Press the Up arrow button and go to the next circuit page settings
(2/8) and repeat GPM and CIRCUIT settings setup. Up to eight (8) circuits can be
assigned.
When finished , Press the MENU button to save and exit to previous menu.
Press Down/Up button to select FILTERING, PRIMING, BACKWASH, VACUUM, or
STATUS. Press the Right button to access settings: Press the Up/Down buttons
to set parameters. See IntelliFlo VF parameter descriptions below:
When finished setting up a parameter, press the Menu button to save the settings
and to return to the IntelliFlo VF setting menu. When finished setting up all of
the IntelliFlo VF pump parameters, press the Menu button until the main screen
displays.
Filtering -Pool Size/Gallons: 0 - 255 (Kgals) - Turnovers per day: (1 - 8)
Filtering Manual Filter GPM: (15 - 130) Default 30 GPM: Manual Filter sets the
flow at which the pump will run if it is turned on manually. The IntelliFlo pump
will only run in the 'Filter' mode during the programmed times. For example,
if the pump is programmed (start/stop times) for the pool circuit to run from
8:00 AM to 4:00 PM everyday. This program or programs are used by IntelliFlo
to calculate at what speed it must run given those 'ON' times to achieve the
turnover(s) for that sized pool for the basic filter mode.
Priming - Max Prime Flow GPM: (30 - 130) Default 55 GPM: Every time the pump
starts this parameter will negotiate the maximum flow of the pump. If the flow
is too high, equipment damage can occur. If the flow is to low the pump will not
prime. This "flow" is system dependent and may require adjustment. The pump
will never flow more than this parameter is set to, however, it is common for the
pump to ramp up and down quickly while priming. Always try to keep this flow as
low as possible for cost savings and safety.
Max Prime Time: (1 - 15 minutes) Default 15 min.: Use this parameter to set the
time that you want IntelliFlo try and prime before it reports an error. Remember
that the IntelliFlo will attain prime every time it starts and goes through this
cycle. The IntelliFlo mechanical seal can withstand about 15 minutes before
severe damage occurs. The lower the time the quicker you will get a priming
error if the system is difficult to prime. A well plumbed pool without having the
strainer removed should prime in less than 30 seconds. If the strainer has been
removed for cleaning and a substantial amount of air is in the system it should
prime in about 60 to 90 seconds on the average, however, all systems will be
different.