Summary of Contents for Pentair SIATA V132-SFE-EV-VIRIDION

  • Page 1 SIATA V132 SFE-EV VIRIDION INSTALLER MANUAL WATER PURIFICATION...
  • Page 2: Table Of Contents

    Installer Manual Siata V132-SFE-EV-VIRIDION - Table of contents Table of contents Generalities ......... . 7 1.1.
  • Page 3 Installer Manual Siata V132-SFE-EV-VIRIDION - Table of contents System sizing ........26 4.1.
  • Page 4 Installer Manual Siata V132-SFE-EV-VIRIDION - Table of contents Programming ........47 6.1.
  • Page 5 Installer Manual Siata V132-SFE-EV-VIRIDION - Table of contents Maintenance ......... 74 9.1.
  • Page 6 Installer Manual Siata V132-SFE-EV-VIRIDION - Table of contents PAGE INTENTIONALLY LEFT BLANK 6 / 110 Ref. MKT-IM-009 / C - 08.06.2018...
  • Page 7: Generalities

    Installer Manual Siata V132-SFE-EV-VIRIDION - Generalities Generalities 1.1. Scope of the documentation The documentation provides the necessary information for appropriate use of the product. It informs the user to ensure efficient execution of the installation, operation or maintenance procedures. The content of this document is based on the information available at the time of publication. The original version of the document was written in English.
  • Page 8: Abbreviations Used

    Installer Manual Siata V132-SFE-EV-VIRIDION - Generalities 1.5. Abbreviations used Assy............Assembly BLFC ............Brine Line Flow Controller BV ............Brine Valve DF............Down Flow DLFC ............Drain Line Flow Controller Inj ............Injector QC............Quick Connect Regen ............Regeneration S&S ............Seals & Spacers SBV............
  • Page 9: Procedure For Technical Support

    Pentair Quality System EMEA products benefit, under specific conditions, from a manufacturer warranty that may be invoked by Pentair’s direct customers. Users should contact the vendor of this product for applicable conditions and in case of a potential warranty claim.
  • Page 10: Scan & Service Application

    Installer Manual Siata V132-SFE-EV-VIRIDION - Generalities 1.10. Scan & Service application Scan & Service mobile application is the ideal support for the maintenance person in his daily business. A simple scan of an identification (ID) label (1) present on the valve with a smartphone gives an instantaneously access to all updated information related to the product, such as: •...
  • Page 11: Safety

    Installer Manual Siata V132-SFE-EV-VIRIDION - Safety Safety 2.1. Safety pictograms definition Caution Warning Warns of a risk of minor injury or major Warns against serious personal injury material damage to the device or and damage to health. environment. Danger Mandatory...
  • Page 12: Hazards

    Installer Manual Siata V132-SFE-EV-VIRIDION - Safety 2.3. Hazards All the safety and protection instructions contained in this document must be observed in order to avoid temporary or permanent injury, damage to property or environmental pollution. At the same time, any other legal regulations, accident prevention and environmental protection measures, as well as any recognized technical regulations relating to appropriate and risk-free methods of working which apply in the country and place of use of the device must be adhered to.
  • Page 13: Hygiene And Sanitization

    Installer Manual Siata V132-SFE-EV-VIRIDION - Safety 2.4. Hygiene and sanitization 2.4.1. Sanitary issues Preliminary checks and storage • Check the integrity of the packaging. Check that there is no damage and no signs of contact with liquid to make sure that no external contamination occurred;...
  • Page 14: Description

    Installer Manual Siata V132-SFE-EV-VIRIDION - Description Description 3.1. Valve versions 3.1.1. Twin pilots The pressure distributor pilot is mounted directly on top of the V132, in this case inlet water is the control fluid and feeds the pilot circuit from the top collector. A controller with a proper camshaft (called twin pilot camshaft) must be mounted on top of the valve and linked to the pilot stems.
  • Page 15: Technical Specifications

    Installer Manual Siata V132-SFE-EV-VIRIDION - Description 3.2. Technical specifications Design specifications/ratings Valve body ..........Glassfiber reinforced ABS Rubber components ....... NBR Valve material certification ....DM174, ACS, W270 Weight (valve with controller)....2.5 kg (max.) Recommended operating pressure ..1.5 - 6 bar Hydrostatic test pressure.......
  • Page 16: Performance Flow Rate Characteristics

    Installer Manual Siata V132-SFE-EV-VIRIDION - Description 3.2.1. Performance flow rate characteristics The graph shows the pressure drop created by the valve itself at different flow rates. It makes it possible to predetermine the maximum flow rate going through the valve depending on the system settings (inlet pressure etc).
  • Page 17: Outline Drawing

    Installer Manual Siata V132-SFE-EV-VIRIDION - Description 3.3. Outline drawing Ref. MKT-IM-009 / C - 08.06.2018 17 / 110...
  • Page 18: Description And Components Location

    Installer Manual Siata V132-SFE-EV-VIRIDION - Description 3.4. Description and components location 3.4.1. Valve with twin pilots Long manifold SFE-EV-VIRIDION Controller Brine Valve Injector Mixing device LCD Display Inlet Down button Regen button Outlet + turbine Up button Volumetric sensor input...
  • Page 19: Valve With External Pilots

    Installer Manual Siata V132-SFE-EV-VIRIDION - Description 3.4.2. Valve with external pilots Note Only the components that differ from the twin pilots valve are described below. Refer to chapter 3.4.1. Valve with twin pilots, page 18 for more information. Brine valve...
  • Page 20: System Regeneration Cycle (5-Cycle Operation)

    Installer Manual Siata V132-SFE-EV-VIRIDION - Description 3.5. System regeneration cycle (5-cycle operation) Service — normal use Untreated water is directed down through the resin bed and up through the riser tube. The hardness ions attach themselves to the resin and are removed from the raw water being exchanged on the resin beads against sodium ions.
  • Page 21 Installer Manual Siata V132-SFE-EV-VIRIDION - Description Note For illustration purpose only. Always verify inlet and outlet marking on the valve. SERVICE NORMAL USE BACKWASH Outlet Inlet Outlet Inlet Drain Valve Valve C2 + C3 BRINE DRAW & SLOW RINSE RAPID RINSE...
  • Page 22 Installer Manual Siata V132-SFE-EV-VIRIDION - Description Backwash flow diagram Service flow diagram Inlet Outlet Inlet Outlet Drain Drain Brine draw diagram Slow rinse diagram Inlet Outlet Inlet Outlet Drain Drain Fast rinse diagram Refill diagram Outlet Outlet Inlet Inlet Drain...
  • Page 23: Options Available On The Valve

    Installer Manual Siata V132-SFE-EV-VIRIDION - Description 3.6. Options available on the valve Backwash flow regulators Backwash flow regulator (1) is positioned in the lower part of the valve. It is accessed by unscrewing protective cap (2). Valves equipped with this accessory are fitted with a flow control set offering the following maximum...
  • Page 24 Installer Manual Siata V132-SFE-EV-VIRIDION - Description Note There is no automatic bypass during a fast rinse cycle. But once the mixing device has been set, it connects the inlet and outlet of the valve. So during the fast rinse phase with a mixing device, it is possible that a flow of untreated water flows into the outlet.
  • Page 25 Installer Manual Siata V132-SFE-EV-VIRIDION - Description Additional hydraulic controls (driver replica) The valve can be equipped with two pairs of connectors for duplicating the position of the hydraulic controls. In order to use the valve, which is delivered with this option, simply remove the blue plugs, at the bottom of the valve, to put a 6 mm flexible tube into the quick connections.
  • Page 26: System Sizing

    Installer Manual Siata V132-SFE-EV-VIRIDION - System sizing System sizing 4.1. Recommendations 4.1.1. Injector/DLFC/BLFC-Valve configuration Tank diameter Resin volume DLFC Injector DF No. DLFC [in] [l/h] [gpm] Washer Brown Blue Blue Black 1450 Black 1450 4.2. Sizing a softener (single unit) 4.2.1.
  • Page 27 Installer Manual Siata V132-SFE-EV-VIRIDION - System sizing The below sizing method can be applied for both residential and industrial softeners. The sizing of a softener must be based upon certain parameters: • inlet water hardness; • peak flow rate and nominal flow rate;...
  • Page 28: Determining The Required Volume Of Resin

    Installer Manual Siata V132-SFE-EV-VIRIDION - System sizing Piping size (internal diameter) Max. flow rate [in] [mm] /h at 3 m/s] 1.25 8.69 13.57 21.20 34.2 49.2 4.2.2. Determining the required volume of resin When sizing a softener, make sure that the volume of resin in the tank (bed volume) will be sufficient so that even when the peak flow rate is reached, the velocity is still between the above values depending on the hardness.
  • Page 29: Resin Exchange Capacity And Capacity Of The Unit

    Installer Manual Siata V132-SFE-EV-VIRIDION - System sizing 4.2.3. Resin exchange capacity and capacity of the unit The resin exchange capacity and capacity of the unit are two different things that should not be confused. The resin exchange capacity is the amount of Ca...
  • Page 30 Installer Manual Siata V132-SFE-EV-VIRIDION - System sizing Salt amount Corresponding resin exchange °f.m °dH.m [g/L capacity in [g/L ] as CaCO [per L [per L resin resin resin resin 58.5 5.85 3.27 62.7 6.27 66.9 6.69 3.74 3.97 75.3 7.53 4.21...
  • Page 31: Valve Configuration

    Installer Manual Siata V132-SFE-EV-VIRIDION - System sizing 4.2.4. Valve configuration Knowing the volume of resin, tank size and specifications of the resin, it is possible to determine the required valve configuration. The resin specification will give the backwash velocity, as well as the brine draw and slow rinse velocity that must be respected in order to ensure a proper regeneration of the unit.
  • Page 32: Cycle Time Calculation

    Installer Manual Siata V132-SFE-EV-VIRIDION - System sizing 4.2.5. Cycle time calculation From this point, the volume of resin, the tank size, the capacity of the softener and the valve configuration are determined. Next step is to calculate the regeneration cycle duration, which depends on the valve configuration and once again on the resin specifications.
  • Page 33: Brine Refill - Cycle

    Installer Manual Siata V132-SFE-EV-VIRIDION - System sizing To calculate the brine draw duration: Knowing the injector draw flow rate at the working pressure: with: brine draw brine draw : brine draw duration [min] brine draw : brine volume to be drawn [L]...
  • Page 34: Injector Flow Rates (Tables)

    Installer Manual Siata V132-SFE-EV-VIRIDION - System sizing 4.4. Injector flow rates (tables) The following tables represent the injector flow rate as a function of the inlet pressure for the different injector sizes. Blue injector performance Brown injector performance Pressure [bar]...
  • Page 35: Installation

    Installer Manual Siata V132-SFE-EV-VIRIDION - Installation Installation Mandatory It is strictly forbidden for not qualified personal, to accede to system’s internal parts to perform any kind of technical action. Be sure to disconnect the electrical power, close the water inlet and depressurize the system before opening the front cover to access internal parts.
  • Page 36 Installer Manual Siata V132-SFE-EV-VIRIDION - Installation Length of connection pipes between valve and lower distribution system The riser tube (distributor) must be cut between 12 to 17 mm, measured from the upper edge of the tank. Remove the sharp edges (1 mm x 45°) to avoid damage to the seal during installation. See drawing below.
  • Page 37: General

    Installer Manual Siata V132-SFE-EV-VIRIDION - Installation 5.3.2. General • Use only brine salts designed for water softening. Do not use ice melt salt, block, or rock salts; • keep the media tank in the upright position. Do not turn on its side, upside down, or drop. Turning the tank upside down may cause media to enter the valve or might plug the upper screen;...
  • Page 38: Mechanical

    Installer Manual Siata V132-SFE-EV-VIRIDION - Installation 5.3.5. Mechanical • Do not use PTFE (plumber’s tape) lubricants such as vaseline, oils, or hydrocarbon-based lubricants. Use only 100% silicone lubricants; • all plastic connections should be hand tightened. PTFE (plumber’s tape) may be used on connections that do not use an o-ring seal.
  • Page 39: Block Diagram And Configuration Example

    Installer Manual Siata V132-SFE-EV-VIRIDION - Installation 5.4. Block diagram and configuration example Block diagram Pressure gauge Main inlet User’s line Check valve to prevent water harm Filter cartridge By-pass Pressure regulator Meter Suggested options Mixing device Can be integrated in the...
  • Page 40: Valve Connection To Piping

    Installer Manual Siata V132-SFE-EV-VIRIDION - Installation 5.5. Valve connection to piping The connections should be hand tightened using PTFE (plumber’s tape) on the threads if using the threaded connection type. In case of heat welding (metal type connection), the connections should not be made to the valve when soldering.
  • Page 41 Installer Manual Siata V132-SFE-EV-VIRIDION - Installation • failure to provide enough vertical compensation may lead to different kinds of damage, either on the valve thread which connect to the tank, or on the female thread connection of the tank that connect to the valve.
  • Page 42: Electrical Connections

    Installer Manual Siata V132-SFE-EV-VIRIDION - Installation 5.6. Electrical connections Micro-switches Transformer Flat cable K-10058 Viridion conductivity probes Terminal board Terminal board Salt sensor Salt sensor Reed contact Volumetric hall Volumetric sensor effect sensor 42 / 110 Ref. MKT-IM-009 / C - 08.06.2018...
  • Page 43: Bypassing

    Installer Manual Siata V132-SFE-EV-VIRIDION - Installation 5.7. Bypassing A bypass valve system has to be installed on all water conditioning systems. Bypass valves isolate the softener from the water system and allow unconditioned water to be used. Service or routine maintenance procedures may also require the system to be bypassed.
  • Page 44: Automatic Bypass

    Installer Manual Siata V132-SFE-EV-VIRIDION - Installation 5.7.2. Automatic Bypass The automatic proportional bypass accessory enhances the system with following functions when fitted upstream of the water treatment system: • supply of untreated water during regeneration cycle 4C. In this cycle the valve does not provide hard water bypass during the regeneration;...
  • Page 45: Drain Line Connection

    Installer Manual Siata V132-SFE-EV-VIRIDION - Installation 5.8. Drain line connection Note Standard commercial practices are expressed here. Local codes may require changes to the following suggestions. Check with local authorities before installing a system. Caution Do not over tighten the hose tightening ring on its plastic support.
  • Page 46: Overflow Line Connection

    Installer Manual Siata V132-SFE-EV-VIRIDION - Installation 5.9. Overflow line connection In the event of a malfunction, power failure, etc, the brine tank overflow fitting will direct “overflow” to the drain instead of spilling on the floor. This fitting should be on the side of the cabinet or brine tank.
  • Page 47: Programming

    Installer Manual Siata V132-SFE-EV-VIRIDION - Programming Programming 6.1. General information SFE-EV-VIRIDION can grant significantly water savings during slow rinse and fast rinse phases. The Viridion functionality is totally transparent for the user, it is activated automatically plugging probe K-10058, no other settings are required.
  • Page 48: Display

    8. Battery operation icon → Appears when the controller is operating on battery. (*): The customer’s logo may be included on the display if requested by the customer. Contact Pentair for further information. 48 / 110 Ref. MKT-IM-009 / C - 08.06.2018...
  • Page 49: Password

    Installer Manual Siata V132-SFE-EV-VIRIDION - Programming 6.3. Password Mandatory The access to the controller operating parameters requires the input of a 4-digit code. Note The default passwords are 0000 for the basic menu and 1111 for the intermediate and advanced menu.
  • Page 50: Basic Programming

    Installer Manual Siata V132-SFE-EV-VIRIDION - Programming 6.4.1. Basic programming Entering the basic menu Press and release to access the basic menu. Enter the password. → See “Access password”, page 49. Current time Set the current time displayed. to modify the digit.
  • Page 51: Intermediate Programming

    Installer Manual Siata V132-SFE-EV-VIRIDION - Programming 6.4.2. Intermediate programming Entering the intermediate menu Press for 5 seconds to access the intermediate menu. Enter the password. → See “Access password”, page 49. Regeneration mode SH0: Time clock regeneration on predefined days;...
  • Page 52 Installer Manual Siata V132-SFE-EV-VIRIDION - Programming Variable brining function Note If the variable brining function is enable, the brine tank will be filled for brine preparation before regeneration. Note After each 10 regeneration cycles, the controller will perform the next regeneration with no optimization of the salt usage.
  • Page 53 Installer Manual Siata V132-SFE-EV-VIRIDION - Programming Outlet water hardness Note This option is displayed only if SH (regeneration mode) is set to 1 or to 2. Mandatory Make sure the mixing device is correctly set up to match with the programmed value.
  • Page 54 Installer Manual Siata V132-SFE-EV-VIRIDION - Programming Resin volume Note The resin volume can be set from 1 to 999 liters. Set the resin volume. to set the volume. Press to validate and switch to the next parameter. Reserve capacity management Note...
  • Page 55 Installer Manual Siata V132-SFE-EV-VIRIDION - Programming Opening time of brine valve Note The display shows the time (in hour) of the brine valve opening to prepare the total volume of brine. Note The opening time can be set from 0h to 24h.
  • Page 56 Installer Manual Siata V132-SFE-EV-VIRIDION - Programming Third regeneration cycle duration Note The duration of the regeneration cycle can be set from 0 (OFF) to 99 minutes. Set the third regeneration cycle duration. to set the duration. Press to validate and switch to the next parameter.
  • Page 57 Installer Manual Siata V132-SFE-EV-VIRIDION - Programming Chlorine cell control duration Note The duration of the chlorine cell control duration can be set from 1 minute to 2C (second regeneration cycle duration). Note This option is displayed only if Cl (chlorine cell control) is set to ON.
  • Page 58 Installer Manual Siata V132-SFE-EV-VIRIDION - Programming Prescaler free for volumetric sensor Note The prescaler free can be set from 0.1 to 99,9. Note The prescaler free is set by default to 14 (applies to SIATA turbine with only one magnet).
  • Page 59 Caution When this command is operated, the brine valve is under full control of the user/installer. Warning Pentair is not responsible for any damage caused by the incorrect use of this command by the user/installer. Press to open the brine valve.
  • Page 60 Installer Manual Siata V132-SFE-EV-VIRIDION - Programming When recalculate the treatable water volume Note The value can be set to IMM (immediate) or dIF (at the end of next regeneration). Note This option is displayed only if SH (regeneration mode) is set to 1 or to 2.
  • Page 61: Advanced Programming

    Installer Manual Siata V132-SFE-EV-VIRIDION - Programming 6.4.3. Advanced programming Entering the advanced menu Press simultaneously for 5 seconds to access to the advanced menu. Enter the password. → See Access password, page 49. Relays activation mode Note The number lit on the upper part of the display identifies the relay to set.
  • Page 62 Installer Manual Siata V132-SFE-EV-VIRIDION - Programming BLFC size Note The value can be set to 00 (gpm), 01 (L/min) or 02 (Custom). Set the BLFC size. to set the size. Press to validate and switch to the next parameter. BLFC range in gpm Note...
  • Page 63 Installer Manual Siata V132-SFE-EV-VIRIDION - Programming Remote regeneration start delay Note Duration in minute of the external signal on port 15/16 of terminal strip to start a regeneration. Set the remote regeneration start delay time. to set the delay time in minute.
  • Page 64 Installer Manual Siata V132-SFE-EV-VIRIDION - Programming End of programming Note The controller saves the modifications and return automatically to service mode. End of programming and modifications saving: 64 / 110 Ref. MKT-IM-009 / C - 08.06.2018...
  • Page 65: Statistics

    Installer Manual Siata V132-SFE-EV-VIRIDION - Programming 6.5. Statistics The statistics menu displays some of the module's historical data. To access to this menu, press and hold for 5 seconds. to switch to the next parameter in the statistics menu. Note...
  • Page 66: Resetting The Statistics

    Installer Manual Siata V132-SFE-EV-VIRIDION - Programming Data Description Automatic regeneration launched in volume mode (SH:02). Automatic regeneration launched in volume mode (SH:02) because maximum number of days for obligatory regeneration has been reached. A xx Automatic regeneration launched in interval mode (SH:03).
  • Page 67: Resetting The Controller

    Installer Manual Siata V132-SFE-EV-VIRIDION - Programming Note The statistical data are reset to 0 and the message CLS flashes on the display for a few seconds. 6.6. Resetting the controller 6.6.1. Resetting the EEPROM To reset the EEPROM to the default values, the controller must be in the service condition (no regeneration cycle running and clock displayed).
  • Page 68: Commissioning

    Installer Manual Siata V132-SFE-EV-VIRIDION - Commissioning Commissioning Note This chapter is available for standard regeneration types. Contact your supplier if the actual regeneration is not standard and if you need assistance. 7.1. Start up procedure 1. With the bypass still in Bypass position plug in the SFE-EV-VIRIDION controller to the power source.
  • Page 69: Sanitization

    Installer Manual Siata V132-SFE-EV-VIRIDION - Commissioning 13. Once in 2C cycle (brine draw) check if the brine is effectively drawn by the valve, and advance to the next cycle. In case controller is programmed for refill after the regeneration, move it to 5C cycle (refill) and perform operations described on steps 9 to 11.
  • Page 70: Operation

    Installer Manual Siata V132-SFE-EV-VIRIDION - Operation Operation 8.1. Display examples • In service in time clock control mode: • In service in volumetric control mode: this display alternate with the display of time clock control mode: • During regeneration: •...
  • Page 71: Recommendations

    Installer Manual Siata V132-SFE-EV-VIRIDION - Operation 8.2. Recommendations • Use only regeneration salts designed for water softening EN973; • for optimal system operation, the use of clean salt free from impurities is recommended (for example salt pellets); • do not use ice melt salt, block, or rock salts;...
  • Page 72: Holiday Function

    Installer Manual Siata V132-SFE-EV-VIRIDION - Operation 8.6. Holiday function When programming the SFE-EV-VIRIDION for a volumetric control mode, you can also activate the “Holiday function”. This feature will place the system in a hibernation state after a predetermined number of day without any water consumption that you program in the advanced menu (See Holiday function, page 57).
  • Page 73: Operation During A Power Failure

    Installer Manual Siata V132-SFE-EV-VIRIDION - Operation Method 2 The controller incorporates a counter that is decreased by one unit at each regeneration. As soon as the counter reaches zero, the salt alarm icon is activated on the display (in three languages: French, German and English) and any regeneration is postponed until the alarm has been manually deactivated.
  • Page 74: Maintenance

    Cleaning and maintenance shall take place at regular intervals in order to guarantee the proper functioning of the complete system. Mandatory The maintenance must be done by a professional certified by Pentair, otherwise the warranty will void. Danger Any valve maintenance operation must be carried out in the absence of hydraulic pressure.
  • Page 75: Controller Battery Replacement

    Installer Manual Siata V132-SFE-EV-VIRIDION - Maintenance 9.2.2. Controller battery replacement Operation Note The battery should be changed every year. Using a screwdriver, unscrew (1). Remove the back panel (2). Using a screwdriver, unscrew (3). Remove the cover (4) by pushing its sides as shown.
  • Page 76: Controller On Valve Installation

    Installer Manual Siata V132-SFE-EV-VIRIDION - Maintenance 9.2.3. Controller on valve installation Operation Using a screwdriver, unscrew (1). Remove the back panel (2). Using a screwdriver, unscrew (3). Remove the cover (4) by pushing its sides as shown. Install the controller (5) on the valve (6).
  • Page 77 Installer Manual Siata V132-SFE-EV-VIRIDION - Maintenance Ref. MKT-IM-009 / C - 08.06.2018 77 / 110...
  • Page 78: Motor Replacement

    Installer Manual Siata V132-SFE-EV-VIRIDION - Maintenance 9.2.4. Motor replacement Operation Using a screwdriver, unscrew (1). Remove the back panel (2). Using a screwdriver, unscrew (3). Remove the cover (4) by pushing its sides as shown. Disconnect the conductivity probe (10).
  • Page 79 Installer Manual Siata V132-SFE-EV-VIRIDION - Maintenance Ref. MKT-IM-009 / C - 08.06.2018 79 / 110...
  • Page 80: Brine Valve Replacement

    Installer Manual Siata V132-SFE-EV-VIRIDION - Maintenance 9.2.6. Brine valve replacement Operation Using a screwdriver, unscrew (1). Remove the back panel (2). Using a screwdriver, unscrew (3). Remove the cover (4) by pushing its sides as shown. Using a wrench, disconnect the brine lines and 6).
  • Page 81 Installer Manual Siata V132-SFE-EV-VIRIDION - Maintenance Ref. MKT-IM-009 / C - 08.06.2018 81 / 110...
  • Page 82: Injector And Injector Screen Cleaning

    Installer Manual Siata V132-SFE-EV-VIRIDION - Maintenance 9.2.7. Injector and injector screen cleaning Operation Using a screwdriver, unscrew (1). Caution Unscrew the screws slowly to prevent gripping between the material and the screws. Remove the collector (2). Remove and clean the injector (4) and the flow breaker (5).
  • Page 83 Installer Manual Siata V132-SFE-EV-VIRIDION - Maintenance Ref. MKT-IM-009 / C - 08.06.2018 83 / 110...
  • Page 84: Twin Pilots Replacement

    Installer Manual Siata V132-SFE-EV-VIRIDION - Maintenance 9.2.8. win pilots replacement Operation Using a screwdriver, unscrew (1). Remove the back panel (2). Using a screwdriver, unscrew (3). Remove the cover (4) by pushing its sides as shown. Using a wrench, disconnect the brine valve (5).
  • Page 85 Installer Manual Siata V132-SFE-EV-VIRIDION - Maintenance Ref. MKT-IM-009 / C - 08.06.2018 85 / 110...
  • Page 86: Pilots (External Drivers Connections) Replacement

    Installer Manual Siata V132-SFE-EV-VIRIDION - Maintenance 9.2.9. Pilots (external drivers connections) replacement Operation Using a screwdriver, unscrew (5). Remove the controller with the pilots (1) from the valve body (6). Unscrew and remove the screws, the nuts and the washers (3).
  • Page 87 Installer Manual Siata V132-SFE-EV-VIRIDION - Maintenance Ref. MKT-IM-009 / C - 08.06.2018 87 / 110...
  • Page 88: Internal Pistons & Seals And Spacers Replacement

    Installer Manual Siata V132-SFE-EV-VIRIDION - Maintenance 9.2.10. Internal pistons & seals and spacers replacement 9.2.10.1 Disassembly Note The procedure to disassemble the inlet and outlet pistons is the same. Operation Note Use special tools from the 2238/05 kit to disassemble the valve internal parts.
  • Page 89 Installer Manual Siata V132-SFE-EV-VIRIDION - Maintenance Ref. MKT-IM-009 / C - 08.06.2018 89 / 110...
  • Page 90 Installer Manual Siata V132-SFE-EV-VIRIDION - Maintenance 9.2.10.2 Assembly Note The procedure to assemble the inlet and outlet pistons is the same. Operation Note Use special tools from the 2238/05 kit to assemble the valve internal parts. Note Before reassembling, grease with silicone grease (cod. 8500):...
  • Page 91 Installer Manual Siata V132-SFE-EV-VIRIDION - Maintenance Ref. MKT-IM-009 / C - 08.06.2018 91 / 110...
  • Page 92: Drain Connection Replacement

    Installer Manual Siata V132-SFE-EV-VIRIDION - Maintenance 9.2.11. Drain connection replacement Operation Unplug the pilots to drain tube (3). Push out the two locking pins (1). Slip off and change the drain manifold (2). Replace and grease all the o-rings with silicone grease (cod. 8500).
  • Page 93: Valve On Tank Assembly

    Installer Manual Siata V132-SFE-EV-VIRIDION - Maintenance 9.2.12. Valve on tank assembly Operation Lubricate the seals with approved silicone grease. Spin the valve (1) onto the tank (2), ensuring the threads are not cross-threaded. Rotate the valve (1) clockwise and freely, without using force until it comes to a stop.
  • Page 94: Troubleshooting

    Installer Manual Siata V132-SFE-EV-VIRIDION - Troubleshooting Troubleshooting Issue Cause Reset and recovery Twin pilot valve: Before closing the inlet water supply, disconnect drain rubber tube and check if there is a leakage from that tube. In case there is one, close inlet water pressure and change the twin pilot assembly.
  • Page 95 Installer Manual Siata V132-SFE-EV-VIRIDION - Troubleshooting Issue Cause Reset and recovery Damage on the inlet internals  o-ring (1) and (2) or on the inlet piston. Dismount the valve and visually check these items. Probable leakage between inlet and Replace...
  • Page 96 Installer Manual Siata V132-SFE-EV-VIRIDION - Troubleshooting Issue Cause Reset and recovery If the water leaking from the drain is softened check for damages on the outlet part of the valve, in particular outlet piston or seals and spacers. Otherwise check for damages on the Leaks to the drain inlet part of the valve.
  • Page 97 Installer Manual Siata V132-SFE-EV-VIRIDION - Troubleshooting Issue Cause Reset and recovery Open the controller box and check the Micro-switch support damaged. integrity of the plastic parts holding the micro-switch. Check if the cam is properly fixed by Cam not fixed.
  • Page 98: Alarm Messages

    Installer Manual Siata V132-SFE-EV-VIRIDION - Troubleshooting 10.1. Alarm messages Inhibit signal There is an inhibit signal input. The following screen alternates with the service screen in the display. Any incoming regeneration is blocked. Salt alarm No more salt in the brine tank. Fill the brine tank with salt if a sensor is present.
  • Page 99 Installer Manual Siata V132-SFE-EV-VIRIDION - Troubleshooting ErEE Error reading parameters from EEPROM. This may appear directly on start-up or after a hardware reset for a few seconds. In this error mode, the controller cannot read the preset parameters. These are reset.
  • Page 100: Spare Parts

    Installer Manual Siata V132-SFE-EV-VIRIDION - Spare parts Spare parts 11.1. Valve parts list 100 / 110 Ref. MKT-IM-009 / C - 08.06.2018...
  • Page 101 Installer Manual Siata V132-SFE-EV-VIRIDION - Spare parts Assembly Min. order Item Part number Description quantity quantity 2230-IN/05 Inlet piston with S&S assy Inlet piston with S&S assy for demineralization 2230-DIN/05 cationic 1918/05 Inlet piston assy K1-1518/05 S&S pack closure nut...
  • Page 102 Installer Manual Siata V132-SFE-EV-VIRIDION - Spare parts Assembly Min. order Item Part number Description quantity quantity K1-2249/05 Drain hose elbow for twin pilot valves Drain hose elbow for twin pilot valves - black K1-2249-N/05 version K1-2249- Drain hose elbow for twin pilot valves with...
  • Page 103 Installer Manual Siata V132-SFE-EV-VIRIDION - Spare parts Assembly Min. order Item Part number Description quantity quantity 22-CK/05 Short manifold 22-CNK/05 Short manifold - black version 22-AK/05 Twin pilot manifold assy 22-ANK/05 Twin pilot manifold assy - black version 22-BK/05 Twin pilot manifold assy with 1/8" connection Twin pilot manifold assy with 1/8"...
  • Page 104: Sfe-Ev-Viridion Spare Parts

    Installer Manual Siata V132-SFE-EV-VIRIDION - Spare parts 11.2. SFE-EV-VIRIDION spare parts 104 / 110 Ref. MKT-IM-009 / C - 08.06.2018...
  • Page 105 Installer Manual Siata V132-SFE-EV-VIRIDION - Spare parts Assembly Min. order Item Part number Description quantity quantity K-10002/01 Black box with cover SFE-EV VIRIDION K-10025/01 Kit electronic board SFE-EV with frame & screws K-10164 Interface SFE-EV SPX/VIR with flat cable 94-R7K/05 Kit motor.
  • Page 106: Fittings

    Installer Manual Siata V132-SFE-EV-VIRIDION - Spare parts 11.3. Fittings For V132 with quick inlet and outlet ports Assembly Min. order Item Part number Description quantity quantity 2265-A/05 Kit fitting ¾" BSP female threaded (nylon) 2265-B/05 Kit fitting 1" BSP female threaded (nylon) 2265-C/05 Kit fitting 1 ¼"...
  • Page 107: Accessories

    Installer Manual Siata V132-SFE-EV-VIRIDION - Spare parts 11.4. Accessories Brine valve Assembly Min. order Item Code Description quantity quantity 60067-03 SBV 2310 - without air check Bypass valve Assembly Min. order Item Code Description quantity quantity BP-D/06 Direct bypass with prop. mixing + check valve...
  • Page 108 Installer Manual Siata V132-SFE-EV-VIRIDION - Spare parts Fittings for bypass Assembly Min. order Item Code Description quantity quantity K-490/05 Reduction 1 ½" female - ¾" male K-491/05 Reduction 1 ½" female - 1" male Meters Assembly Min. order Item Code...
  • Page 109: Disposal

    This will help to reduce the impact on the environment, health, safety and help to promote recycling. Pentair does not collect used product for recycling. Contact your local recycling center for more information.
  • Page 110 www.pentairaquaeurope.com...