Schedules Menu - Pentair EasyTouch PNP 5 Owner's Manual

Pool and spa control systems
Table of Contents

Advertisement

Programming EasyTouch: Schedules

Schedules Menu

Use the Schedules menu to create programs to schedule start and stop times to automatically run
equipment, such as pumps and lights. Any circuit can be programmed to switch on and off at a specific time
on every or any specific day of the week. The number of programs that can be created for circuits are as
follows:
Up to 12 total programs can be created for all circuits combined.
One circuit can have up to a maximum of 9 programs.
Using the Schedules menu
Use the Schedules menu features to program operating schedules for the pool, spa and auxiliary circuits:
Getting There
MENU
SCHEDULES
SPA
0
POOL
0
AUX 1
0
AUX 2
0
SPA
0/0
Mode: None
SPA
0/0
Mode: New
SPA
1/1
Mode: Schedule
_
08:00A - 05:00P
smtwtfs SS: N
SPA
1/1
Mode: Egg Timer
Timer: 12:00
SPA
1/1
Mode: Once Only
_ _ _
08:00A
s
t
tfs
m
w
SPA
1/1
Mode: New
SPA
1/1
Mode: None
SPA
1/1
Mode: Delete
Choose the circuit to program
Up/Down button: Select the generic circuit name to program: Spa, Pool, Aux 1-7,
Feature 1- 8, Aux 1-3 and Aux Extra. Aux Extra is only available if the Solar output
is not being used. See Solar button on page 5 for details. The current number
of programs for each circuit is displayed opposite the circuit name. A circuit
can have up to 9 programs (9/9). Three additional programs can be assigned to
another circuit or three separate circuits for a maximum of 12 programs.
Create a new program
The current number of programs for each circuit is indicated opposite to the
circuit name. 0/0 indicates no programs assigned to this circuit.
Right button: To move to the "Mode" selection.
Up/Down button: Select New to create a new program. Use "None" when a
circuit has existing programs and you wish to exit the "Mode" selections without
modifying the existing programs.
Choose the type (Mode) of program to run
After selecting "New" the current program number (1/1) for this circuit is
displayed.
Right button: To move to the "Mode" selections.
Up/Down button: Choose the program to run: Schedule, Egg Timer, Once Only,
New, Delete, and None. If there are existing programs assigned to this circuit,
use these buttons to view and select the existing program settings.
Mode Selection:
Schedule: Set start, stop times and the day(s) of the week to automatically switch
pool/spa circuits on or off. Default run time for the "Schedule" feature is 8:00 AM
to 5:00 PM. If you program the start and stop times the same the schedule is will
run for 24 hours. Note: SS: N (Smart Start) is displayed if a light circuit is being
scheduled (see page 45).
Egg Timer: A one time program that switches on a function at a specific time, and
counts down the preset time to the switch off the function. After the "Egg Timer"
schedule has finished, the system can be operated in manual mode. The "DON'T
STOP" option allows a circuit to run continuously until its switched off manually.
Once Only: Schedule a circuit to switch on at a particular time on a onetime basis.
New: press the Right button to create a new program.
Delete: Select the program and press the Right button to delete it.
None: Press the Right button to exit the "Mode" selections without modifying the
program.
Page 38