Delays; Heat Pump Com (Ultratemp ® Heat Pump) - Pentair EasyTouch PNP 5 Owner's Manual

Pool and spa control systems
Table of Contents

Advertisement

Advanced Settings: Delays

Delays

Setup which functions (pool/spa, and valves) to assign the delay feature. Delays can be assigned to the
following equipment.
Heater Cool-Down Delay Cancel: Shuts Filter Pump off immediately.
2-Speed Filter Pump five-minute START on HIGH SPEED Delay Cancel: Shifts pump to low
speed.
Automatic Pool Cleaner START Delay: Starts Cleaner Pump immediately, without normal delay
in which the filter pump first runs for 5 minutes.
Automatic Pool Cleaner SOLAR Delay: Allows Cleaner Pump to run even though solar delay
has shut it off for 5 minutes.
Some heaters require a cool down cycle before being switched off. This can be setup to run the filter pump
an additional ten minutes to dissipate residual heat built up inside the heater combustion chamber. You can
also cancel the delay feature.
To assign a delay feature:
Getting There
MENU
SETTINGS
DELAYS
Press the Up/Down buttons to select YES to enable COOLDOWN delays for the pool and spa circuits. Select
YES to use delays for valves. Press the Menu button to save and to return to the Settings menu options.
Delay Cancel Menu
Use the Delay Cancel feature for service or testing purposes. For convenience, on a onetime basis, the
Delay Cancel feature will cancel the above safety delays. Please note, generally there is no need to cancel
any of the above delays except for servicing or testing the system.
To activate Delay Cancel:
Getting There
MENU
DELAY CANCEL
F. Circuits
Lights
Heat
Delay Cancel
Heat Pump COM (UltraTemp
The Pentair UltraTemp Heat Pump is currently unavailable in Australia and New Zealand. Other
brand heat pumps still be used with the EasyTouch though. Refer to Page 18 for heat pump
connection and configuration.
Delays
DELAYS
Cooldown: No
Valves:
Up/Down button: Select Delay Cancel.
Right button: Use this button activate Delay Cancel for one time only. "Delay
Cancelled" is displayed after pressing the Right button.
Press the Menu button to return to the main screen.
Heat Pump)
®
No