General operation
The PROBE UNIT, located in the technical room, collects information on the water quality and communicates this to the CONTROL CENTRE.
The CONTROL CENTRE is also located in the technical room and activates different equipment in the pool. For IntelliFlo® and IntelliChlor®, this
information is sent via a RS485 bus. In this way, IntelliPool® also collects information and comments from IntelliPool® and IntelliChlor®. By using
a wireless proprietary protocol at the centre of the control, it sends and receives information and controls from the other system component. The
INTERNET RELAY permits remote access to a system, using a PC, tablet or smartphone. The INTERNAL DISPLAY informs the pool owner of the
main pool parameters while the REMOTE CONTROL permits the lights and water feature to be activated in terms of pool aspects. The RADIO
RELAY assures radio communications between the elements, while collecting the temperature of the ambient air. In this configuration, the system
has all necessary elements to assure proper functioning of the pool.

Specific settings for the VSD drive and VSF IntelliFlo

The IntelliFlo® VS and VF pumps do not require specific settings.
However, for IntelliFlo® VSD, be sure to:
- Disable the freezing prevention function in the pump
- Set the minimum and maximum speeds at the same values as in the IntelliPool® menu to manually obtain similar protection during functioning of
the pump.
- Determine if you would like the priming function to be activated. Consult the VSD and VSF manual for this function. When it is activated on the
pump, the pre-programmed priming becomes active. Note that this can lead to unintended results with some equipment.
Please note: IntelliPool® will also control the pump keypad; stopping the pump from the keypad is not possible when IntelliPool® is
active. Use IntelliPool® or in an emergency, actuate the main power interrupter to stop the pump.