Intelliflo ® Menu - Pentair EasyTouch PNP 5 Owner's Manual

Pool and spa control systems
Table of Contents

Advertisement

Programming EasyTouch: IntelliFlo
IntelliFlo
Menu
®
Connecting power to an IntelliFlo pump
The IntelliFlo pump is designed to be permanently connected to its power source. No relay connected outlet
is required. The IntelliComm cable controls the starting and stopping of the pump. When the IntelliFlo pump
is connected to the EasyTouch automation system, the drive must be powered up to receive and respond to
the RS-485 serial communication from the automation system. The EasyTouch PNP includes dedicated 15A
permanent power outlets (one on the EasyTouch PNP 5 and two on the EasyTouch PNP 10).
How many IntelliFlo pumps will EasyTouch support?
EasyTouch can support a total of two IntelliFlo pumps in any combination with up to eight GPMs or RPMs
per pump. For example pumps can be connected to EasyTouch as follows:
1 IntelliFlo VF + 1 IntelliFlo VS
2 IntelliFlo VF
2 IntelliFlo VS
Selecting the IntelliFlo PUMP TYPE
Getting There
MENU  SETTINGS  INTELLIFLO  PUMP#1
Pump #1
Pump #2
Changing Pump1's
Type will config
it to default.
Continue ? N
Pump Type
Speeds
Priming
Status
Pump #1 Type
Type: VS
Pump #1
1/8
RPM: 1200
Circuit:
[ POOL
]
Pump Type
Speeds
Priming
Status
Pump Priming
Time: 0
Speed: 1000
Pump Type
Speeds
Priming
Status
Pump Status
RPM: 1200
Watts: 10
Status: GOOD
Up/Down button: Choose Pump #1. (To assign a circuit to Pump #2, be sure
to change the pump to "ADDRESS 2" on the pump's control panel, see below
instructions).
Right button: Select Pump #1.
Right button: Select Pump Type. Note: To change the current pump type for
Pump #1. press the Up/Down button and select Y, then press the Right button. To
continue to the Pump #1 settings menu, press the Right button (or Menu to exit).
SELECT PUMP TYPE: Up/Down buttons: Choose VS or VF.
Menu button: Press the MENU button to save selection and return to the selected
pump's menu settings (see VS, and VF pump settings descriptions below).
INTELLIFLO VS SPEEDS SETTING:
Down button: Choose Speeds.
Right button: Access the IntelliFlo VS speed (RPM) settings for Pump #1.
Up/Down button: Select the circuit number 1 of 8 (1/8).
Right button: Move to RPM to change the pump speed.
Up/Down buttons: Set speed of the pump from 400 to 3450 RPM in increments of
10 RPM. The default speed for each circuit correspond to the four speed buttons
on the IntelliFlo VS control panel is: Speed 1 button 750 RPM, Speed 2 button
1500 RPM, Speed 3 button 2350 RPM, and Speed 4 button 3110 RPM.
INTELLIFLO VS PRIMING SETTING:
Down button: Choose SPEEDS.
Right button: Access the priming settings.
Up/Down button: Adjust the priming time from 0 to 5 minutes.
Right button: Move to SPEED (RPM) to change the pump speed.
Up/Down buttons: Set speed of the pump from 400 to 3450 RPM in increments of
10 RPM. The default speed for each circuit correspond to the four speed buttons
on the IntelliFlo VS control panel is: Speed 1 button 750 RPM, Speed 2 button
1500 RPM, Speed 3 button 2350 RPM, and Speed 4 button 3110 RPM.
INTELLIFLO VS STATUS SETTING:
Down button: Choose STATUS.
Right button: View the current VS status.
Menu: Press MENU to exit.
Page 34

Advertisement

Table of Contents
loading

This manual is also suitable for:

Easytouch pnp 10

Table of Contents