IntelliFlo® menu
IntelliPool® permits you to obtain the most efficient and economical use of your IntelliFlo® pump. The system can work with any type of
IntelliFlo® pump equipped with a variable frequency VS, VF or VSD reader.
Before setting the speed in the menu in IntelliPool®, we advise you to launch an operational test with the aim of establishing the most functional
speed settings. You can do this before the actual installation or by disconnecting the IntelliFlo® communication cable. In this way, you can use
the pump keypad to quickly change speeds on the pump. Consult your manual for a more precise explanation of the way to change the speeds
on your IntelliFlo® pump. IntelliFlo® VF clients need to use the "ste speed" button.)
IntelliFlo: 45000
IntelliFlo speed range
Chlorinator filtration speed
Heating filtration speed
Open cover speed
Aux1 filtration speed
Auxiliary filtration speed
Filtration speed of filter clean
IntelliFlo - Warning
1 2 3 4 5 6 7 8
#2: DRIVE TEMPERATURE WARNING
Save modifications
Comments on the alarms in progress are displayed (pass the
mouse over the alarm concerned).
IntelliChlor® menu
This menu makes it possible to adjust the operating duration of IntelliChlor® if a pool cover is present and to learn of the type of warning
IntelliChlor: 45000
Running duration cover closed
Save modifications
IntelliChlor - Warning
1 2 3 4 5 6 7
#2: LOW SALT
26
1,200
Min:
rpm
3,000
Max:
rpm
1,300
Min:
rpm
3,000
Min:
rpm
2,400
Min:
rpm
2,400
Set point:
rpm
2,400
Aux 2 set point:
rpm
2,400
Aux 3 set point:
rpm
2,400
Aux 4 set point:
rpm
2,600
Set point:
rpm
0m 10s
Duration:
0h 15min
/day
8
Minimum speed: Find the minimum speed which is capable of generating
sufficient flows in the pool. IntelliPool® will not work at a speed slower than
this. The lower this speed, the more you will save on energy.
Maximum speed: this is usually the speed required for backwashing. The
pump will not work at higher speeds than this to prevent the equipment from
being damaged.
Heating pump: Your heating pump requires a minimum flow rate; select a
speed at which the heat pump can function. You can adjust the speed until
the heating pump compressor is activated. Set the speed 5% higher;
Salt chlorinator: A minimum flow must be set. Determine the necessary
triggering speed of your electrolyser and set it at a value above 5%.
Aux. speeds: for the auxiliary speeds, 3 options are possible (can be
selected from the drop-down menu)
1. No change: The pump continues at the normal filtration speed while the
Aux function is activated. (Example: garden lighting)
2. OFF: The pump stops when the Aux outlet is active (for example robotic
cleaning)
3. Setting a specific speed: The pump turns at a specific speed while the aux
function is active (for example: fountain).
Automatic cleaning valve: If the Aux function is configured as an automatic
backwash valve, the specific BW (backwash) speed and the time can be set
in this section.
With these parameters in place, IntelliFlo® will run at the most economical
setting as a minimum, but will increase its speed only when this is required
for the specified functions.
Limited operating function of the electrolyser if the pool cover is present
Comments on the alarms in progress are displayed
(pass the mouse over the alarm concerned).