2.8
Programming a Pause in Test Sequence
"PAUSE" is a mode selection that allows a test sequence to be stopped while test leads are
changed or other operations performed. A 15-character user programmable message will be
displayed on the screen when in PAUSE mode and the test will continue when the [START]
button is pressed or when START is initiated via remote I/O. The Under Test relay on the
remote I/O can also be cycled during PAUSE if required.
PAUSE is encountered the tester stops, displays PAUSE and 15-character message until START
button is pressed again (or START is initiated via remote I/O).
This mode is applicable to the Sentry 10, 20 and 30 Plus instruments. With the instrument in
'stand-by' status, press [F1] = PROGRAM. If continuing the 5-step example from ¶2.7, you are
already in program mode and on the AC test mode page. This example shows a GC test as
Step1, an AC test as Step 2, a DC test as Step 3, an IR test as Step 4 and finally how to program
a Pause as Step5. Follow the
individual Pause mode parameters. Enter a message (length 1-15 characters) for the operator.
STEP
VOLT
:
[F1] = NEW
HIGH
:
Program
TIME
:
Step 5 = PA
Voltage is 0
STEP 5/5
VOLT
:
Select
HIGH
:
PA
TIME
:
Test Mode
Select Mode
STEP 5/5
PAUSE
:
Enter
UNDER TEST SIGNAL
Pause
Message
1 - 15 CHAR.
STEP 5/5
PAUSE
:
Enter
UNDER TEST SIGNAL
Pause
Message
1 - 15 CHAR.
Continued on Next Page.
Operation
green
arrows (!) on the right side of this diagram to program the
5/5
AC
LOW
ARC
0.000kV
RAMP
0.500mA
FALL
3.0s
RMT
LOCK
AC
LOW
ARC
0.000kV
RAMP
0.500mA
FALL
3.0s
RMT
LOCK
PA
PAUSE MODE
:
OFF
RMT
LOCK
PA
CHANGE-DUT
:
OFF
RMT
LOCK
During the test sequence when
:
OFF
FIRST
:
OFF
:
OFF
MORE..
:
OFF
NEXT
EXIT
OFST
ERR
:
OFF
UP
:
OFF
:
OFF
DOWN
:
OFF
NEXT
EXIT
OFST
ERR
UP
DOWN
NEXT C.
CANCEL
OFST
ERR
UP
DOWN
NEXT
CANCEL
OFST
ERR
F1
To change value of highlighted box.
F2
To delete or insert a test step.
F3
To move highlighted box to MODE.
F4
To exit programming mode.
F1
Set MODE = PA
F2
To move highlighted box to
F3
PAUSE
F4
To enter message:
F1
1 - 15 characters: * + , - . /
0 -9 and A - Z
F2
F3
To move cusor to next character.
F4
To erase message.
F1
F2
F3
To move highlighted box to UNDER.
F4
Page 43 of 85