I mportant Safety Instructions
2 B
WARNING – To reduce the risk of severe injury or death, all instruction and installation of safety
equipment must be performed in accordance to ANSI 156.10 for pedestrian usage.
F unction Description of Circuits
3 1 B
F unction of Kill
7 1 B
If the kill circuit is closed on the master or slave control, the control(s) will ignore all signals and
immediately close door(s) at normal speed.
F unction of Locks
7 2 B
The control has an available output of 18 VAC/DC for external locks and lock modules. This output
will require an add on module by others to interface the external lock.
P ush and Go
7 3 B
Initiates the automation of the door by way of the act of "pushing the door". Additional after market
hardware is required.
P ower Failure
7 4 B
After a power failure there is a warm up safety feature of 5 seconds. This allows the time for the
safety system to power up and observe the surrounding conditions.