P Lanned Maintenance Checklist - Besam ASSA ABLOY Swingmaster 900 Service And Installation Manual

Table of Contents

Advertisement

P lanned Maintenance Checklist

2 5 B
Measure / Adjust Speeds – Measure to ANSI/BHMA A156.10 and local codes;
adjust if necessary.
Measure / Adjust Forces – Measure to ANSI/BHMA A156.10 and local codes;
adjust if necessary.
Measure / Adjust Time Delays – Measure to ANSI/BHMA A156.10 and adjust if
necessary.
Check Functioning – Mats, Sensors, Operator/Control, and Push Plates per
device checklist and AAADM.
Check Signage – Are all signs in place, readable, and in good condition?
Check Door Hinging / Mechanical Soundness – all attachments, covers, arms,
crash bars, etc.
Check Finger Guards, Glass and Glass Stops, Trip Hazards, Rails, Sharp
Edges.
Check Emergency Egress (if so equipped).
Check all wiring for good connections, proper insulation and clearance from
moving parts.
Go through Daily Safety Checklist with facility manager.
Besam Entrance Solutions
53
1/31/2008

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents