G Eneral Tips / Safety Concerns; S Ummary Installation - Besam ASSA ABLOY Swingmaster 900 Service And Installation Manual

Table of Contents

Advertisement

G eneral Tips / Safety Concerns

9 B
For enhanced security and vandalism protection, mount the operator access to the interior of the
building whenever possible.
Ensure that the power is off before installing.
Insure that the door leaf and the wall are properly reinforced at the installation points.
Inspect the door hinges before installation to ensure that they are in good repair.

S ummary Installation

1 0 B
This is only a summary of the installation process. See the rest of this manual for detailed
information.
1. Establish installation height.
2. For surface applied installations, locate header horizontally above door so that the centerline of
spindle to centerline of hinge dimension is correct.
3. Install the header.
4. Mount the operator.
5. Install the control unit so that the PC board is facing the removable access cover.
6. Attached all ground cables to ground bolt. (Reference section titled, "Part Identification &
Options, for ground bolt location.)
7. For surface applied, attach the arm shoe to the door. For concealed installations, mount drive arm
to shaft.
8. For surface applied installations, mount the rest of the drive arm. For concealed installations,
mount/hang the door.
9. Complete all electrical connections to other operators or optional equipment.
10. Adjust the control unit for optimal and safe performance, in accordance with ANSI/BHMA
A156.10 specifications for pedestrian applications.
11. Apply safety signage to the door(s).
12. Train facility manager in proper product operation.
13. Explain to the facility manager, the daily safety checklist described in the owner's manual, and
leave a copy of the owner's manual with the facility manager.
Besam Entrance Solutions
15
1/31/2008