E Lectrical Connections And Adjustments; C Onnections - Besam ASSA ABLOY Swingmaster 900 Service And Installation Manual

Table of Contents

Advertisement

E lectrical Connections and Adjustments

2 1 B
Important Notice!
The Swingmaster, when installed and set up correctly, is a safe automatic power door operator, but
incorrect settings can create a safety hazard. For safety reasons, never set the opening or closing
speed faster than necessary to handle the traffic situation to your door. Please refer to the
ANSI/BHMA A156.10 excerpt in the back of this manual. A correctly adjusted door is a safe door.

C onnections

6 4 B
During any work with the electrical connections, the main power must be disconnected.
Using bracket US03-0579-03, mount the control onto the header using existing holes and hardware
supplied in kit. Be sure that the terminal block is facing the cover.
1. Connect the motor plug for either left or right hand operation.
2. Connect the cam system switch harness for either left or right hand operation.
3. Connect the protective earth ground cable to the header ground bolt.
4. Connect neutral and hot to connector and plug into control.
5. Connect an ON-OFF-HOLD OPEN switch to control or plug it into the CUHub.
6. Connect the mains and test that the system is working properly by utilizing the hold open switch.