T Roubleshooting - Besam ASSA ABLOY Swingmaster 900 Service And Installation Manual

Table of Contents

Advertisement

T roubleshooting

2 3 B
FAULT
The door does not open
– motor does not start.
Control has power but
still no operation
The motor starts but
door does not open, or
does not open properly.
The door does not open
to the required angle.
The door does not open
fully when impulsed
during closing.
Besam Entrance Solutions
CHECK
Is there 120 VAC
power at control box?
Is On/Off/Hold Open
switch set to off?
Is push plate working
(if used)?
Is safety sensor
activated?
Is the arm system
loose?
Are the door hinges or
arm binding
anywhere?
Is there a door strike
(electric) in the
system?
Loose motor coupling.
Loose motor coupling.
Is the operator or the
mechanical doorstop
adjusted?
Are the door
hinges/pivots
defective?
Is there binding in the
door swing or arm
system?
FIX/REMEDIES
Check / replace / reset main panel fuse or breaker.
Note: if it repeatedly trips, there is a short.
Check wiring from panel to control for an open circuit.
Note: there may be an in-line on/off wall switch.
Change switch position to on.
Check push plate connections to control. Check for
proper operation of push plate by using a multimeter to
check for 0 ohms when the switch is pressed, as
measured at the control inputs.
Check the motor cable plug on the control unit.
Check with a multimeter for 0 ohms, and replace with a
fuse of the same rating. Continued blowing of fuses
suggests either a short, miswiring or lastly a bad control
unit.
Check if kill is active.
Repair/adjust safety sensor.
Remove power, close door fully and adjust and tighten
arm per installation instructions.
Correct the binding condition.
Check wiring and adjust strike.
Retighten.
Retighten
Readjust
Replace and/or lubricate.
Repair/replace of re-align as necessary
50