Software diagnostics

The level transmitter system can alert users to potential problems by:
• Posting messages on the Ohmview 2000 message screen
• Energizing the output relay
• Distinctly changing the current loop output
• Tracking the current status and history in the Gauge status screens

Alarm types

Table 5.1
Name
Diagnostic
alarm
Analog alarm
Process
alarm
X-ray alarm
LFXG-H Installation and Operation Guide
D
IAGNOSTICS AND REPAIR
Chapter 5
Provides information about the level gauge system and alerts
users when periodic procedures are due.
Sets the current loop mA output to 2 mA or 22 mA when the
detector outputs 0 counts.
The process alarm lets the relay output trip when the process
level is above (high limit) or below (low limit) a setpoint.
Distinctly changes the current loop mA output in response to a
marked increase in the radiation field. This prevents control
problems when external radiographic sources are in the area for
vessel inspections.
Description
Diagnostics and repair
C
H A P T E R
5
73