Tdr sensor for continuous level and
interface measurement of liquids.
four-wire modbus
converter version in second chamber
polished rod probe (100 pages)
1.2 Principle of operation Scope of delivery Area of application The scope of delivery encompasses: VEGAFLEX 62 is a level senor with cable or rod • the VEGAFLEX 62 level sensor electrode for continuous level measurement. • documentation It is designed for industrial use in all areas of...
Provide a reliable separation between the exter- nal energy source and the mains circuits acc. to DIN VDE 0106 part 101. The VEGA power supply units VEGATRENN 149AEx, VEGASTAB 690, VEGADIS 371 as well as all VEGAMETs meet this requirement.
VEGADIS 61 4…20 mA Fig. 4: Wiring plan, single chamber housing Connect cable screen here, connect ground terminal on housing exterior to ground as prescribed (low-impedance). The two terminals are galvanically connected. ® VEGAFLEX 62 – 4 … 20 mA/HART...
Page 7
Connect cable screen here, connect ground terminal on housing exterior to ground as prescribed (low-impedance). housing exterior to ground as prescribed (low-impedance). The two terminals are galvanically connected. The two terminals are galvanically connected. ® VEGAFLEX 62 – 4 … 20 mA/HART...
6 sec (ti : 0 s, 0 … 63 %) The time required by the output signal to reach 63 % of the actual height after a jump of the input variable. ® VEGAFLEX 62 – 4 … 20 mA/HART...
Page 9
Metal silo with smooth walls diameter 12 m diameter 9 m diameter 6 m diameter 3 m Cable length (m) Cable length (m) Plastic granules Cement Cable length (m) Cable length (m) ® VEGAFLEX 62 – 4 … 20 mA/HART...
Page 10
– blocked distance bottom 0 mm Cable 1 m … 60 m – blocked distance top 300 mm – blocked distance bottom 250 mm 100% 100% Fig. 11: Measuring ranges of VEGAFLEX 62 ® VEGAFLEX 62 – 4 … 20 mA/HART...
Page 11
M20 x 1.5 (cable-ø 5 … 9 mm)/½ NPT – double chamber housing M20 x 1.5 (cable-ø 5 … 9 mm)/½ NPT M16 x 1.5 (cable-ø 4 … 8 mm) Spring-loaded terminals for wire cross-section up to 2.5 mm² ® VEGAFLEX 62 – 4 … 20 mA/HART...
Page 12
ATEX II 1G, 1/2G, 2G EEx ia IIC T6, ATEX II 1/2G, 2G EEx d ia IIC T6, ATEX II 1/2D IP6X T, ship approvals Deviating data with Ex applications: see separate safety instructions. ® VEGAFLEX 62 – 4 … 20 mA/HART...
Page 14
~ 79 ~ 116 ø 77 ø 77 ø 84 ø 84 M20x1,5 M20x1,5/ ½ ½ N ½ NPT M20x1,5/ ½ NPT with display Low cover without High cover with PLICSCOM PLICSCOM ® VEGAFLEX 62 – 4 … 20 mA/HART...