ArcSystem Pro Multi-Cell
Updating the Fixture Software
ETC recommends using UpdaterAtor software to manage software updates. For more information on
UpdaterAtor, download the UpdaterAtor Software Quick Guide for free from etcconnect.com.

Maintenance

WARNING:
system before installation, maintenance, cleaning, or any other system modification could
result in serious injury or death.
AVERTISSEMENT :
débrancher toutes les sources d'alimentation du système avant l'installation, l'entretien, le
nettoyage ou toute autre modification du système peut causer des blessures graves ou la
mort.
De-energize main feed to ArcSystem and follow appropriate Lockout/Tagout procedures as
mandated by NFPA 70E. It is important to note that electrical equipment such as breaker
panels can present an arc flash hazard if improperly serviced. This is due to the high
amounts of short-circuit current available on the electrical supply to this equipment. Any
work must comply with OSHA Safe Working Practices.
WARNING:
performing any cleaning and maintenance.
AVERTISSEMENT :
refroidir avant d'effectuer un nettoyage ou un entretien.
WARNING:
cannot be serviced or operated safely.
AVERTISSEMENT :
qu'un dispositif de déconnexion de l'alimentation ne soit accessible.
CAUTION:
fixture enclosure. Clean using compressed air or a soft cloth. Keeping the components of
the enclosure clean facilitates efficient cooling and extends LED longevity.
NEVER spray liquids into the fixture.
NEVER spray compressed air into a fixture that is powered-up.
Note:
the manufacturer or his service agent or a similar qualified person.
A can of compressed air or oil-free air from an air compressor set at a low setting can be used to
blow through the vent holes and remove dust or other debris. Dust buildup can cause overheating
and premature shutdown.
All components can be cleaned using compressed, oil-free air as described above or a clean micro-
fiber cloth. The use of any liquid cleaning solution is not recommended.
Inspect all mounting hardware for wear and, if necessary, clean using compressed, oil-free air or a
soft, lint-free cloth.
ArcSystem Pro Multi-Cell
RISK OF DEATH BY ELECTRIC SHOCK! Failure to disconnect all power to the
RISQUE DE MORT PAR DÉCHARGE ÉLECTRIQUE! Négliger de
Disconnect the fixture from power and DMX and allow it to cool before
Débrancher la lampe de son alimentation et du DMX et la laisser
Circuits that are installed without an accessible power disconnect device
Il est imprudent d'utiliser ou de réparer les circuits installés sans
Check for excessive dust or debris in the heat-dissipating fins around the entire
The light source(s) contained within ArcSystem luminaires shall only be replaced by
Page 22 of 24