ETC Installation Guide
ArcSystem Pro Multi-Cell
Connect the Maintained Input
1.
See
Wire and Terminal Specifications on page 10
length. Prepare wires accordingly.
2.
Remove the three screws securing the wiring compartment cover to the fixture. The cover is
grounded by a tether to the enclosure. Set the screws aside.
3.
Terminate ground.
a.
Locate the WAGO connector on the ground wire (green) connected to the bottom of the
wiring compartment (
b.
Run a ground wire (typically green/yellow) through conduit to a free position on the
WAGO connector.
c.
Lift up the orange clip, insert the ground wire, and press the clip down onto the wire.
d.
Tug gently to make sure the wire is secure.
4.
Terminate neutral.
a.
Locate the WAGO connector on the neutral wire (white) from the input.
b.
Run a neutral wire (typically white or grey) through conduit to a free position on the
WAGO connector.
c.
Lift up the orange clip, insert the neutral wire, and press the clip down onto the wire.
d.
Tug gently to make sure the wire is secure.
5.
Terminate line (hot).
a.
Locate the WAGO connector on the line (hot) wire (black) from the input.
b.
Run a line (hot) wire through conduit to a free position on the WAGO connector.
Note:
brown, orange, or yellow.
c.
d.
Terminate DMX
DMX In and DMX Thru cables terminate to RJ45 connectors. DMX is installed in a daisy chain
topology and includes one pair of wires (data +, data -) plus an ISO ground (common). ETC
recommends Cat5e (or better) minimum 24 AWG conductors terminated to T568B standard. Up to
32 fixtures can be connected per DMX run.
1.
If using hard wired DMX, plug the RJ45 connector into the DMX
in port on the rear of the fixture.
2.
If linking additional fixtures via DMX, plug a RJ45 cable into the
DMX thru port on the rear of the fixture.
Note:
You must terminate the last fixture in line with a 120 Ω
resistor. To purchase an RJ45 terminator, please
contact your ETC customer service representative and
request part number N4086.
ArcSystem Pro Multi-Cell
Line (hot) wire color varies based on voltage and region but is typically black,
Lift up the orange clip, insert the line wire, and press the clip down onto the wire.
Tug gently to make sure the wire is secure.
ArcSystem fixtures are not self-terminating.
).
Page 13 of 24
for specification of wire and strip
RJ45 Pinout Information
Pin
1
2
7&8
Description
Data +
Data -
ISO ground
(common)
ETC
Need help?
Do you have a question about the ArcSystem Pro Multi-Cell RDM and is the answer not in the manual?
Questions and answers