ETC Source 4WRD II Installation And User Manual

ETC Source 4WRD II Installation And User Manual

Hpl to led retrofit (ce)
Hide thumbs Also See for Source 4WRD II:

Advertisement

Quick Links

Source 4WRD II
HPL to LED Retrofit (CE)
Installation and User Manual
Version 1.9.0
Part Number: 7067M1210-1.9.0 Rev A
Released: 2020-10

Advertisement

Table of Contents
loading

Summary of Contents for ETC Source 4WRD II

  • Page 1 Source 4WRD II HPL to LED Retrofit (CE) Installation and User Manual Version 1.9.0 Part Number: 7067M1210-1.9.0 Rev A Released: 2020-10...
  • Page 2 To view a list of ETC trademarks and patents, go to etcconnect.com/ip. All other trademarks, both marked and not marked, are the property of their respective owners. ETC intends this document, whether printed or electronic, to be provided in its entirety.
  • Page 3: Table Of Contents

    Install the Source 4WRD II Retrofit Install the Fixture Attach Hanging Clamp and Safety Cable Connect Cables Configure the Fixture RDM Values Focus the Fixture Set the Z-adjustment Adjust the Yoke Position Shape the Beam Source 4WRD II Installation and User Manual...
  • Page 4 Troubleshoot the Source 4WRD II Clean and Maintain the Fixture Clean the Fixture Store the Retrofit Clean the Lenses Clean the Reflector Clean 5° and 10° Polymer Lenses Source 4WRD II Installation and User Manual...
  • Page 5: Introduction

    90 CRI Daylight (Gallery) variants. Retrofit kit, shown installed on a Source Four fixture body Note: The Source 4WRD II LED retrofit kit is not compatible with Source Four LED, Fresnel, PAR, PARNel, or jr fixtures. Source 4WRD II Installation and User Manual...
  • Page 6 ETC support website at support.etcconnect.com or the main ETC website at etcconnect.com. If none of these resources are sufficient, contact ETC Technical Services directly at one of the offices identified below. Emergency service is available from all ETC offices outside of normal business hours.
  • Page 7: Safety

    Safety The Source 4WRD II fixture is intended for professional use only. Read the entire manual before using this equipment. WARNING: This fixture must be installed by a qualified electrician in accordance with all national and local electrical and construction codes and regulations.
  • Page 8 WARNING: Note the following safety warnings before use: The Source 4WRD II LED is not user serviceable. Field • modification of the Source 4WRD II LED will void your ETC warranty. Do not use the fixture below 5°C (41°F). •...
  • Page 9 38°C (100°F) Weight Source 4WRD II LED retrofit kit only: 1.69 kg (3.73 lb) • Source 4WRD II LED installed on 26° fixture with yoke: 5.48 kg  • (12.1 lb) Optical Compatible with all ETC Source Four lens tubes. Source 4WRD II Installation and User Manual...
  • Page 10: Retrofit The Fixture

    Retrofit kit User interface and navigation buttons Wire the Power Connector If you ordered a Source 4WRD II retrofit without a power connector, wire the connector in accordance with all national and local electrical codes: Brown = Live • Blue = Neutral •...
  • Page 11 4. Remove the lamp housing from the fixture body. Note: The burner assembly is no longer needed. If you would like ETC to recycle the burner assembly, contact ETC Technical Services for more information. See Help from ETC Technical Services on page 2.
  • Page 12 4. Gently slide the Source 4WRD II LED onto the fixture body and threaded post while guiding the LED tower into the lamp housing hole, as shown in the following image. Take care to prevent contact between the LEDs and the reflector. Source 4WRD II Installation and User Manual...
  • Page 13 Source 4WRD II LED, directly above the Z-adjustment knob. 6. Pull gently to verify secure attachment. Set the Z- 7. Set the Z-adjustment using the Z-adjustment knob. See adjustment on page 15 Source 4WRD II Installation and User Manual...
  • Page 14: Install The Fixture

    Attach Hanging Clamp and Safety Cable The hanging clamp attaches the fixture to the mounting pipe and allows you to adjust the position of the mounted fixture. ETC recommends using 1.5 in schedule 40 pipe. Tightly fasten the hanging clamp to the yoke, and then connect the safety cable.
  • Page 15: Connect Cables

    See Configure the Fixture on page 14 WARNING: Do not use or store the Source 4WRD II fixture below 5°C (41°F). When the fixture has been stored or transported in cold temperatures, allow it to warm to room temperature for a minimum of 1 hour before applying power.
  • Page 16 (You may need to adjust dimmer settings for optimal fixture control). In addition to the recommended settings in the following tables, you may need to increase the SCR Off Time from the default setting. Contact ETC for assistance in changing the SCR Off Time, or any other CEM classic, CEM+, or CEM3 settings.
  • Page 17 Note: When line-dimming the fixture, performance may vary based on the control settings of the dimmer. For this reason, ETC recommends using line-dimming for level-setting or for architectural dimming. ETC recommends testing the Source 4WRD II fixture on all existing dimmers that you want to use.
  • Page 18: Configure The Fixture

    . The display will read (Level = Full). Use the down L.99 arrow to decrease the level to a percentage of full ( = 99%, L.98 = 98%, etc.). You can set levels from 0%–100% (full). RDM Values Parameter RDM PID Value Manufacturer ID...
  • Page 19: Focus The Fixture

    Source 4WRD PAR or PARNel Fixture Body, turn the Z-adjustment knob toward PEAK until the knob becomes loose, and then tighten the Z-adjustment knob an additional quarter turn. This sets the LED light source into the appropriate position within the fixture. Source 4WRD II Installation and User Manual...
  • Page 20: Adjust The Yoke Position

    Set the Angle within the Yoke 1. Loosen the yoke locking knob. Do not remove the knob. 2. Tilt the fixture to the desired position. 3. Tighten the yoke locking knob to secure in position. Yoke locking knob Source 4WRD II Installation and User Manual...
  • Page 21 The pattern holder slot is on the top side of the barrel and in front of the shutters. It accommodates A-size, B-size, and glass pattern holders. Because the Source 4WRD II fixture aperture is 3 inches wide, ETC recommends A-size patterns for maximum effectiveness.
  • Page 22: Troubleshoot The Source 4Wrd Ii

    Troubleshoot the Source 4WRD II The following error codes may be seen on the Source 4WRD II user Help from ETC interface. For more troubleshooting assistance, see Technical Services on page 2 (OTP) indicates that the fixture has gone into over-temperature •...
  • Page 23: Clean And Maintain The Fixture

    5°C (41°F), make sure it is in an upright Store with LEDs facing up position as shown. Allow it to warm to room temperature for a minimum of one hour before applying power. Source 4WRD II Installation and User Manual...
  • Page 24: Clean The Lenses

    50%-50% mixture of each to clean the glass surface. 3. Slide the lens tube back into the barrel with the color frame retaining clip on top. Reinstall the beam focus knob and retaining bolt. Source 4WRD II Installation and User Manual...
  • Page 25: Clean The Reflector

    The barrel should be firmly attached and the triangles should be aligned. 7. Reinstall the barrel rotation knob and tighten the retaining bolt. 8. Reinstall the LED lamp housing and tighten the attachment screw. Install the Source 4WRD II Retrofit on page 8 Source 4WRD II Installation and User Manual...
  • Page 26: Clean 5° And 10° Polymer Lenses

    9. Set the lens back in the lens tube with the ridged side facing the front of the tube. Reinstall the lens brackets. 10. Slide the lens tube back into the barrel with the retaining clip for the color frame on top. Reinstall the beam focus knob. Source 4WRD II Installation and User Manual...
  • Page 27 Source 4WRD II Installation and User Manual...
  • Page 28 Conta c t etcconnect.com/contactETC © 2020 Electronic Theatre Controls, Inc. Product information and specifications subject to change. ETC intends this document to be provided in its entirety. Trademark and patent info: etcconnect.com/ip 7 0 6 7 M 1 2 1 0 -1 .9 .0 Rev A Released 2020-10...

Table of Contents