3.5.2 Control Circuit Terminal Functions
The functions of the control circuit terminals are shown in Table 3.9. Use the appropriate terminals for the
correct purposes.
Type
No.
Signal Name
1
Forward run/stop command
2
Reverse run/stop command
3
External fault input
4
Fault reset
Se-
S
Multi-step speed reference 1
5
quence
(Master/auxiliary switch)
input
input
signals
6
Multi-step speed reference 2
7
Jog frequency reference
8
External baseblock
11
Sequence input common
15
15 V power output
33
−15 V power output
13
Master speed frequence refer-
Master speed frequence refer
Analog
Analog
ence
input
14
signals
g
16
Multi-function analog input
17
Control common
Shield wire, optional ground
12
line connection point
9
Running signal (1NO contact)
Running signal (1NO contact)
10
25
Zero speed detection
Se-
quence
quence
output
26
Speed agree detection
signals
signals
27
Open-collector output common
18
19
Fault output signal (SPDT)
p
20
21
Frequency output
Analog
Analog
22
output
p
Common
signals
i
l
23
Current monitor
*
When driving an L load, such as a relay coil, always insert a flywheel diode as shown in Figure 3.18.
External power:
48 V max.
Table 3.9
Control Circuit Terminals
Forward run when CLOSED; stopped when OPEN.
Reverse run when CLOSED; stopped when OPEN.
Fault when CLOSED; normal
when OPEN.
Reset when CLOSED
Auxiliary frequency reference
when CLOSED.
Multi-step setting 2 when
CLOSED.
Jog run when CLOSED.
Inverter output stopped when
CLOSED.
15 V power supply for analog references
−15 V power supply for analog references
−10 to 10 V/−100% to 100%
0 to 10 V/100%
4 to 20 mA/100%, −10 to +10 V/−100% to 100%
0 to +10 V/100%
−10 to 10 V/−100% to 100%
0 to 10 V/100%
Operating when CLOSED
Operating when CLOSED.
Zero level (b2-01) or below
when CLOSED
Within ±2 Hz of set frequency
when CLOSED.
Fault when CLOSED across 18 and 20
F l
h
CLOSED
g
(
)
Fault when OPEN across 19 and 20
Fault when OPEN across 19 and 20
0 to 10 V/100% frequency
5 V/Inverter's rated current
Coil
50 mA max.
Fig 3.18
Flywheel Diode Connection
3 - 21
3.5 Wiring Control Circuit Terminals
Function
Multi-function contact in-
puts
(Command signals can be
(Command signals can be
selected by setting H1-01 to
H1-06.)
H1-06.)
Auxiliary analog input
(H3-05)
M l i f
Multi-function outputs
i
18
d 20
Multi-function analog moni-
tor 1
(H4-01, H4-02)
Multi-function analog moni-
tor 2
(H4-04,H4-05)
Flywheel diode
The rating of the flywheel diode
must be at least as high as the cir-
cuit voltage.
Signal Level
24 VDC, 8 mA
Photocoupler isolation
Photocoupler isolation
15 V
(Max. current: 20 mA)
−15 V
(Max. current: 20 mA)
−10 to 10 V (20 kΩ),
0 to 10 V (20 kΩ)
4 to 20 mA (250 Ω)
−10 to 10 V (20 kΩ),
0 to 10 V (20 kΩ)
Dry contacts
Contact capacity:
Contact capacity:
1 A max. at 250 VAC
1 A max. at 30 VDC
Open-collector output
Open-collector output
50 mA max. at 48 V*
Dry contacts
y
C
Contact capacity:
i
1 A max. at 250 VAC
1 A max at 250 VAC
1 A max. at 30 VDC
0 to ± 10 V max. ± 5%
0
10 V
5%
2 mA max.
2 mA max
3