Pulse Monitor Card: F7-01

J
When using a PO-36F Pulse Monitor Card, set the output pulse in constant F7-01.
D
User
User
Constant
Name
Number
Frequency multiple
F7-01
selection
Settings
D
Setting
0
1F
1
6F
2
10F
3
12F
4
36F
"F" indicates the output frequency (Hz). For example, if "0" (1F) is set, when the output frequency
D
is 60 Hz there will be an output of 60 pulses per second. (Duty 50%)
Change
g
during
during
Setting
Setting
Unit Factory
Range
Opera-
tion
0 to 4
×
Description
1 x Inverter output frequency
6 x Inverter output frequency
10 x Inverter output frequency
12 x Inverter output frequency
36 x Inverter output frequency