User Constants
8.2.2 Autotuning Constants: C
Name
Con
Con-
stant
Num-
Display
ber
S-curve charac-
teristic time at ac-
C2-01
celeration start
SCrv Acc @ Start
S-curve charac-
teristic time at ac-
C2-02
celeration end
SCrv Acc @ End
S-curve charac-
teristic time at de-
celeration start
C2 03
C2-03
SCrv Dec @
Start
S-curve charac-
teristic time at de-
C2-04
celeration end
SCrv Dec @ End
C
Constant
Number
Slip compensation
gain
C3 01
C3-01
Slip Comp Gain
8
Slip compensation
primary delay time
C3 02
C3-02
Slip Comp Time
Slip compensation
limit
C3-03
C3 03
Slip Comp Limit
Slip compensation
selection during re-
generation
C3-04
Slip Comp Regen

S-curve Acceleration/Deceleration: C2

J
Description
All sections of the S-curve characteristic
All sections of the S-curve characteristic
time are set in seconds units.
:When the S-curve characteristic time is
set, the accel/decel times will increase
by only half of the S-curve characteris-
tic times at start and end
tic times at start and end.
Run com-
Run com-
ON
ON
mand
Output frequency
C1-02
C1-01
C1-01

Motor Slip Compensation: C3

J
Name
Description
Display
Used to improve speed accuracy
when operating with a load.
:Usually setting is not necessary.
When actual speed is low, in-
crease the set value.
Wh
When actual speed is high, de-
t l
crease the set value.
In flux vector control mode this
function becomes gain to com-
pensate for slip caused by tem-
perature variation.
Slip compensation primary delay
time is set in ms units.
:Usually setting is not necessary.
Adjust when slip compensation
responsiveness is low, or speed
is not stabilized
is not stabilized.
When responsiveness is low, de-
crease the set value.
When speed is not stabilized, in-
crease the set value.
Sets the slip compensation limit as
a percentage of motor rated slip
a percentage of motor rated slip.
0: Disabled.
1: Enabled.
:When the slip compensation
during regeneration function
has been activated, as regenera-
tion capacity increases momen-
tion capacity increases momen-
tarily, it may be necessary to
use a braking option (braking
resistor, Braking Resistor Unit
or Braking Unit.)
Setting
S
Factory
Range
Setting
0.0 to
0.20
2.50
2.50
0.0 to
0.20
2.50
2.50
OFF
OFF
0.00 to
C1-03
C 03
0.20
0.20
2 50
2.50
C1-04
C1-04
0.00 to
Time
0.00
2.50
2.50
S
Setting
Factory
Range
Setting
0.0 to
1.0 *
1.0
2.5
2 5
d i hi h d
0 to
200
200 *
10000
10000
0 to 250
0 to 250
200
200
0, 1
0
8 - 12
Control Methods
Change
Change
during
V/f
Open
Opera-
V/f
with
Loop
tion
Vector
Vector
PG
A
A
A
×
A
A
A
×
A
A
A
A
A
A
×
×
A
A
A
×
Control Methods
Change
Change
during
V/f
Open
Opera-
V/f
with
Loop
tion
Vector
Vector
PG
B
B
B
B
×
×
f
f
A
A
A
A
×
×
×
×
A
A
A
A
×
×
×
×
A
A
×
×
Page
Flux
A
7 - 52
A
7 - 52
A
A
7 - 52
7 52
A
7 - 52
Page
Flux
7 - 34
B
B
7 - 53
7 53
7 54
7 - 54
×
×
7 54
7 - 54
×
×
7 - 54
×