Selecting 1-Step And 2-Step Frequency References; Timing Chart For Multi-Step Speed And Jog References - YASKAWA VARISPEED-616G5 Instruction Manual

200v class 0.4 to 75kw (1.2 to 110kva) 400v class 0.4 to 300kw (1.4 to 460kva)
Hide thumbs Also See for VARISPEED-616G5:
Table of Contents

Advertisement

The following table shows which frequency is selected by each possible combination of multi-step
D
speed and JOG reference settings.
Terminal 5
Multi-step speed
reference 1
OFF
ON
OFF
ON
OFF
ON
OFF
ON

Selecting 1-step and 2-step Frequency References

To use the master frequency (analog terminal 13 or 14), set b1-01 to 1.
D
To use frequency reference 1 (d1-01), set b1-01 to 0.
D
To use the auxiliary frequency reference (analog terminal 16), use the factory setting.
D
To use frequency reference 2 (d1-02), set H3-05 to 1F.
D
Frequency
reference
RUN/STOP
Multi-step speed reference 1
Multi-step speed reference 2
Multi-step speed reference 3
JOG reference
Fig 6.10
Terminal 6
Multi-step speed
Multi-step speed
reference 2
OFF
OFF
ON
ON
OFF
OFF
ON
ON
Reference 5
Reference 4
Reference 3
Reference 2
Auxiliary speed
Reference 1
Master speed
ON
OFF
ON
OFF
ON
OFF
OFF

Timing Chart for Multi-step Speed and JOG References

6 - 15
Terminal 7
Terminal 8
JOG reference
reference 3
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
Reference 8
Reference 7
Reference 6
ON
6.1 Common Settings
Selected frequency
Reference 1: d1-01 (master
speed frequency)
Reference 2: d1-02 (auxilia-
ry speed frequency)
Reference 3: d1-03
Reference 4: d1-04
Reference 5: d1-05
Reference 6: d1-06
Reference 7: d1-07
Reference 8: d1-08
Jog frequency: d1-09
JOG frequency
OFF
ON
6