Hardware Protection: L8 - YASKAWA VARISPEED-616G5 Instruction Manual

200v class 0.4 to 75kw (1.2 to 110kva) 400v class 0.4 to 300kw (1.4 to 460kva)
Hide thumbs Also See for VARISPEED-616G5:
Table of Contents

Advertisement

Hardware Protection: L8

J
Name
C
Constant
Number
Display
Protect selection for
internal DB resistor
L8-01
(Type ERF)
DB Resistor Prot
Overheat pre-alarm
level
L8 02
L8-02
OH Pre-Alarm Lvl
Operation selection
after overheat pre-
alarm
L8-03
OH Pre-Alarm Sel
Input open-phase
protection selection
L8 05
L8-05
Ph Loss In Sel
Output open-phase
protection selection
L8 07
L8-07
Ph Loss Out Sel
Ground protection
selection
L8 10
L8-10
Gnd Det Sel
Carrier frequency re-
duction selection
L8 17
L8-17
L-Spd IGBT Prtct
Description
0: Disabled (no overheating
protection)
1: Enabled (overheating protec-
1: Enabled (overheating protec-
tion)
Sets the detection temperature for
the Inverter overheat detection
pre-alarm in °C.
:The pre-alarm detects when the
l
d t t
h
th
:Th
cooling fin temperature reaches
the set value.
Sets the operation for when the In-
verter overheat pre-alarm goes
ON.
0: Decelerate to stop in decelera-
tion time C1-02.
1: Coast to stop
2: Fast stop in fast-stop time
p
p
C1 09
C1-09.
3: Continue operation (Monitor
display only.)
:A fault will be given in setting
0 to 2 and a minor fault will be
given in setting 3.
0: Disabled
1: Enabled (Detects if input cur-
rent open-phase, power supply
p
p
, p
pp y
voltage imbalance or main cir-
lt
i b l
i
i
cuit electrostatic capacitor de-
terioration occurs.)
0: Disabled
1: Enabled (Output open-phase
detected at less than 5% of In-
verter rated current.)
:W e app ed oto capac ty s
:When applied motor capacity is
small for Inverter capacity, out-
ll
i
put open-phase may be de-
tected inadvertently or open-
phase may not be detected. In
this case, set to 0 (Disabled.)
0: Disabled
1: Enabled
1 E bl d
0: No carrier frequency reduction
1: With carrier frequency reduc-
tion
2: For factory adjustments
3: For factory adjustments
:If the metallic noise (carrier
(
noise) generated from the mo-
i )
t d f
th
tor at low speeds (less than 6
Hz) becomes a problem, set
L8-17 to 0 and L8-19 to 1.
However, do not set L8-17 or
L8-19 to 0 when using V/f and
open-loop vector control.
8 - 41
8.2 Programming Mode Constants
Change
Change
S
Setting
Factory
during
Opera-
Range
Setting
V/f
tion
0, 1
0
B
×
50 to
A
A
95
95
×
×
130
130
0 to 3
3
A
×
A
A
0, 1
0, 1
0
0
×
×
A
A
0, 1
0, 1
0
0
×
×
A
A
0, 1
0, 1
1
1
×
×
A
A
0 to 3
0 to 3
1
1
×
×
Control Methods
V/f
Page
Open
Flux
with
Loop
Vector
Vector
PG
B
B
B
7 - 95
A
A
A
A
A
A
7 95
7 - 95
A
A
A
7 - 95
A
A
A
A
A
A
7 - 95
7 95
A
A
A
A
A
A
7 95
7 - 95
A
A
A
A
A
A
−−
A
A
A
A
7 95
7 - 95
×
×
8