YASKAWA VARISPEED-616G5 Instruction Manual page 345

200v class 0.4 to 75kw (1.2 to 110kva) 400v class 0.4 to 300kw (1.4 to 460kva)
Hide thumbs Also See for VARISPEED-616G5:
Table of Contents

Advertisement

Name
No.
(Display)
Mid. output frequency 2
: 2
E1-11
(Mid Frequency B)
Mid. output frequency voltage 2
E1-12
Mid Voltage B)
Base voltage
: 2
E1-13
(Base Voltage)
Motor rated current
E2-01
(Motor Rated FLA)
Motor rated slip
E2-02
(Motor Rated Slip)
Motor no-load current
E2-03
(No-Load Current)
Number of motor poles
E2-04
(Number of Poles)
Motor line-to-line resistance
E2-05
(Term Resistance)
Motor leak inductance
E2-06
(Lead Inductance)
Motor iron saturation coefficient 1
E2-07
(Saturation Comp 1)
Motor iron saturation coefficient 2
E2-08
(Saturation Comp 2)
Motor mechanical loss
E2-09
(Mechanical Loss)
Motor iron loss for torque compensation
E2-10
(Tcomp Iron Loss)
Motor 2 control method selection
E3-01
(Control Method)
Motor 2 max. output frequency
E4-01
(V/F2 Max Freq)
Motor 2 max. voltage
: 1
E4-02
(V/F2 Max Voltage)
Motor 2 max. voltage frequency
E4-03
(V/F2 Base Freq)
Motor 2 mid. output frequency 1
E4-04
(V/F2 Mid Freq)
Motor 2 mid. output frequency voltage 1
E4-05
(V/F2 Mid Voltage)
Motor 2 min. output frequency
E4-06
(V/F2 Min Freq)
Motor 2 min. output frequency voltage
E4-07
(V/F2 Min Voltage)
Motor 2 rated current
: 1
E5-01
(Motor 2 rated FLA)
Motor 2 rated slip
: 1
E5-02
(Motor 2 Slip Freq)
Motor 2 no-load current
: 1
E5-03
(Motor 2 No-load I)
Motor 2 number of poles
: 1
E5-04
(Motor 2 # poles)
Motor 2 line-to-line resistance
E5-05
(Motor 2 Term Ohms)
Motor 2 leak inductance
: 1
E5-06
(Motor 2 Leak)
PG constant
F1-01
(PG Pulse/Rev)
Operation selection at PG open circuit
F1-02
(PG Fdbk Loss Sel)
Operation selection at overspeed
F1-03
(PG Overspeed Sel)
Operation selection at deviation
F1-04
(PG Deviation Sel)
PG rotation
F1-05
(PG Rotation Sel)
* 1. Not displayed for some models depending on software version No.
* 2. Setting for 200 V class Inverters. For 400 V class Inverters, double the value.
* 3. Setting unit and initial setting depend on Inverter capacity.
* 4. Depends on the control method (A1-02).
* 5. Factory setting in the parentheses is for 3-wire sequence.
Table 12.1
User Constants (Continued)
Factory
Setting
Setting
0.0
: 2
0.0
0.0
1.90
: 3
2.90
: 3
1.20
: 3
4
9.842
: 3
18.2
: 3
0.50
0.75
0.0
14
: 3
: 1
2
: 1
60.0
200.0
: 2
: 1
60.0
: 1
3.0
11.0
: 1
: 2
0.5
2.0
: 1
: 2
1.9
: 3
2.90
: 3
1.20
: 3
4 poles
9.842
: 3
18.2
: 3
600
1
1
3
0
12 - 17
Name
No.
(Display)
PG division rate (PG pulse monitor)
F1-06
(PG output Ratio)
Integral value during accel/decel enable/disable
F1-07
(PG Ramp PI/I Sel)
Overspeed detection level
F1-08
(PG Overspd Level)
Overspeed detection delay time
F1-09
(PG Overspd Time)
Excessive speed deviation detection level
F1-10
(PG Deviate level)
Excessive speed deviation detection delay time
F1-11
(PG Deviate Time)
Number of PG gear teeth 1
F1-12
(PG# Gear Teeth 1)
Number of PG gear teeth 2
F1-13
(PG# Gear Teeth 2)
PG open-circuit detection time
F1-14
(PGO Time)
Bi-polar or uni-polar input selection
F2-01
(AI-14 Input Sel)
Digital input option
F3-01
(DI Input)
Channel 1 monitor selection
F4-01
(AO Ch1 Select)
Channel I gain
F4-02
(AO Ch1 Gain)
Channel 2 monitor selection
F4-03
(AO Ch2 Select)
Channel 2 gain
F4-04
(AO Ch2 Gain)
Channel 1 output monitor bias
F4-05
(AO Ch1 Bias)
Channel 2 output monitor bias
F4-06
(AO Ch2 Bias)
Channel 1 output selection
F5-01
(DO-02 Ch1 Select)
Channel 2 output selection
F5-02
(DO-02 Ch2 Select)
Output mode selection
F6-01
(DO-08 Selection)
Frequency multiple selection
F7-01
(PO-36F Selection)
Transmission option (SI-F/G)
F8-01
(E-15 Det Sel)
External fault input level from transmission op-
F9-01
tion (FF0 Selection)
: 1
External fault detection from transmission op-
F9-02
tion (EF0 Detection)
: 1
Action for external fault from transmission op-
F9-03
tion (EF0 Fault Act)
: 1
Transmission option trace sampling time
F9-04
(Trace Sample Time)
: 1
Torque reference/ torque limit selection from
F9-05
non-SI-K2 transmission cards
(Torq Ref/Lmt Sel)
Operation selection for non-SI-K2 transmission
F9-06
error detection
(BUS Fault Sel)
Multi-function input (terminal 3)
H1-01
(Terminal 3 Sel)
Multi-function input (terminal 4)
H1-02
(Terminal 4 Sel)
Multi-function input (terminal 5)
H1-03
(Terminal 5 Sel)
Multi-function input (terminal 6)
H1-04
(Terminal 6 Sel)
12.5 User Constants
Factory
Setting
Setting
1
0
115
0.0
: 4
10
0.5
0
0
: 1
2.0
0
0
2
1.00
3
0.50
0.0
0.0
0
1
0
1
: 1
1
0
0
1
0
1
1
24
14
3 (0)
: 5
4 (3)
: 5
12