Overspeed Settings: F1-03, F1-8, F1-09; Pg Speed Deviation Settings: F1-04, F1-10, F1-11 - YASKAWA VARISPEED-616G5 Instruction Manual

200v class 0.4 to 75kw (1.2 to 110kva) 400v class 0.4 to 300kw (1.4 to 460kva)
Hide thumbs Also See for VARISPEED-616G5:
Table of Contents

Advertisement

Basic Operation
6.4.1 PG Speed Control Card Settings
6
Settings
D
Setting
0
Deceleration to stop using deceleration time 1 (C1-02).
1
Coast to stop
2
Emergency stop using the emergency-stop time (C1-09).
3
Continue operation (To protect the motor and machinery, this is not normally set.)

Overspeed Settings: F1-03, F1-8, F1-09

Overspeed refers to an excessive motor speed.
D
Set the conditions (level and time) for detecting overspeed and the stopping method that is used when
D
an overspeed is detected.
User
User
Name
Constant
Number
Operation selection
F1-03
at overspeed
Overspeed detection
F1-08
level
Overspeed detection
F1-09
delay time
Settings
D
Setting
0
Deceleration to stop using deceleration time 1 (C1-02).
1
Coast to stop
2
Emergency stop using the emergency-stop time (C1-09).
3
Continue operation (To protect the motor and machinery, this is not normally set.)
F1-08 and F1-09 Settings
D
Constant F1-08 sets the overspeed detection level as a percentage of the maximum output frequency.
Constant F1-09 sets the length of time in seconds that the motor speed must exceed the overspeed
detection level in order to generate an overspeed fault.

PG Speed Deviation Settings: F1-04, F1-10, F1-11

After an agreement of the actual motor speed and the reference speed has been detected (depending
D
on the setting in F1−04), the differrence between the actual motor speed ( caluculated from the PG feed-
back value) and the frequency reference must exceed the PG speed deviation detection level set in
F1−10 and the allowable time set in F1−11 to detect a PG speed deviation(DEV.)
These constants set the conditions (level and time) for detecting PG speed deviation and the stopping
D
method that is used when a PG speed deviation is detected.
User
User
Constant
Name
Number
Operation selection
F1-04
at deviation
Excessive speed
F1-10
deviation detection
level
Excessive speed
F1-11
deviation detection
delay time
Settings (F1-04)
D
Setting
0
Deceleration to stop using deceleration time 1 (C1-02).*1
1
Coast to stop*1
2
Emergency stop using the emergency-stop time (C1-09).*1
3
Continue operation (Displays "DEV" and continues control.)*1
4
Deceleration t to stop using deceler action time 1 ( C1−02)*2
5
Coast to stop *2
Function
Change
g
during
during
Setting
Setting
Unit Factory
Opera-
Range
tion
0 to 3
×
0 to 120
%
×
0.0 to 2.0
s
×
Function
Change
g
during
during
Setting
Setting
Unit Factory
Opera-
Range
tion
0 to 7
×
0 to 50
%
×
0.0 to 10.0
s
×
Function
6 - 30
Valid Access Levels
Factory
Open
V/f
V/f with
Setting
Loop
Control
PG
Vector
1
B
×
×
A
115
×
×
A
0.0
×
×
Valid Access Levels
Factory
Open
V/f
V/f with
Setting
Loop
Control
PG
Vector
B
3
×
×
10
A
×
×
0.5
A
×
×
Flux
Vector
B
A
A
Flux
Vector
B
A
A