User Constants
8.2.6 Terminal Constants: H
Constant
C
Number
Multi-function input
H2-01
(terminal 9-10)
Multi-function input
H2-02
(terminal 25-27)
Multi-function input
H2-03
(terminal 26-27)
Setting
Value
0
During run (ON: run command is ON or voltage is being output)
1
Zero-speed
2
Frequency agree 1: (Detection width L4-02)
Desired frequency agree 1
3
[ON(: Output frequency = ±L4-01, detection width in L4-02) and during frequency agree]
4
Frequency (Four) detection 1 (ON: +L4-01 ≥ output frequency ≥ −L4-01, detection width in L4-02)
Frequency (Four) detection 2
5
(ON: Output frequency ≥ +L4-01 or output frequency ≤ −L4-01, detection width in L4-02)
6
Inverter operation ready
7
During DC bus undervoltage (UV) detection
8
During baseblock (ON: during baseblock)
9
Frequency reference selection (ON: Frequency reference from Operator)
A
Run command selection (ON: Run command from Operator)
B
Overtorque detection 1 NO (NO contact: Overtorque detection at ON)
Loss of frequency reference (Effective when operation selection is "1" for L4-05 frequency reference
C
missing)
D
Braking resistor fault (ON: Resistor overheat or braking transistor fault)
E
Fault (ON: Faults other than CPF00, CPF01 have occurred.)
F
Not used. (Set when the terminals are not used.)
10
Minor fault (ON: Alarm displayed)
11
Fault reset command active
12
Timer function output
8
13
Frequency agree 2 (Detection width: L4-04)
Desired frequency agree 2
14
[ON(: Output frequency = L4-03, detection width in L4-04) and during frequency agree]
15
Frequency detection 3 (ON: Output frequency ≤ −L4-03, detection width in L4-04)
16
Frequency detection 4 (ON: Output frequency ≥ −L4-03, detection width in L4-04)
17
Overtorque detection 1 NC (NC Contact: Torque detection at OFF)
18
Overtorque detection 2 NO (NO Contact: Torque detection at ON)
19
Overtorque detection 2 NC (NC Contact: Torque detection at OFF)
1A
During reverse run (ON: During reverse run)
1B
During baseblock 2 (OFF: During baseblock)
1C
Motor selection (Second motor under selection)
1D
Regenerating (ON: Regenerating)
1E
Restart enabled (ON: Restart enabled)
1F
Motor overload (OL1) pre-alarm (ON: 90% or more of the detection level)
20
Inverter overheat (OH) pre-alarm (ON: Temperature exceeds L8-02 setting)
30
During torque limit (current limit) (ON: During torque limit)
31
During speed reference limit. (ON: During speed reference limit)
33
Zero-servo end (ON: Zero-servo function completed)
During run 2 (ON: Frequency output, OFF: Base block, DC injection braking, initial excitation, opera-
37
tion stop.

Multi-function Outputs: H2

J
Name
Display
Terminal 9 Sel
Terminal 25 Sel
Terminal 26 Sel

Multi-function Output Functions

READY: After initialization, no faults
Setting
S
Factory
Range
Setting
0 to 37
0
0 to 37
1
0 to 37
2
Function
8 - 30
Control Methods
Change
Change
during
V/f
Open
Opera-
V/f
with
Loop
Vector
tion
Vector
PG
B
B
B
×
B
B
B
×
B
B
B
×
Control Methods
V/f
Open
loop
V/f
w/
Vec-
PG
tor
f
f
f
f
f
f
f
f
f
f
f
f
f
f
f
f
f
f
f
f
f
f
f
f
f
f
f
f
f
f
f
f
f
f
f
f
f
f
f
f
f
f
f
f
f
f
f
f
f
f
f
f
f
f
f
f
f
f
f
f
f
f
f
f
f
f
f
f
f
f
f
f
f
f
f
f
f
f
f
f
f
f
f
f
×
×
×
f
f
f
f
f
f
f
f
f
×
×
f
×
×
×
×
×
×
f
f
f
Page
Flux
B
7 - 77
B
7 - 77
B
7 - 77
Flux
Page
vec-
tor
7 - 78
f
7 - 78
f
7 - 90
f
7 - 90
f
7 - 90
f
7 - 90
f
f
f
f
f
f
7 - 94
f
7 - 91
f
f
9 - 2
f
9 - 6
f
f
7 - 45
f
7 - 90
f
7 - 90
f
7 - 90
f
7 - 90
f
7 - 94
f
7 - 94
f
7 - 94
f
f
f
f
f
7 - 93
f
7 - 78
f
7 - 78
f
f
f
7 - 78
f
7 - 78
f

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents