Removing the ionizing air knife
1
2
Refitting the ionizing air knife
1
Product manual - Feather Duster V2
3HAX010000210 Revision: A
Action
Disconnect the connectors.
Remove the ionizing air knife with its
bracket by removing the screws.
CAUTION
Support the ionizing air knife while remov-
ing it; otherwise, it may drop suddenly after
the screws at one end are removed.
Action
Refit the ionizing air knife with its bracket.
© Copyright 2018 ABB. All rights reserved.
5.2.5 Replacing the ionization unit
Note
xx1800001579
xx1800001580
Note
xx1800001580
Screw: M6x30 (4 pcs)
Tightening torque: 10 Nm
Continues on next page