10 Electrical connection
10.2
Control units
10.2.1
CU-ESD
The CU-ESD can be equipped with extension units, EXU-SI and/or EXU-SA, depending on the functions
required.
See page 12 or 14.
Motor
SPTE OPSP CLSP
Spring tension
Opening speed
Closing speed
10.2.2
Arm system selection
Factory set arm configuration is PUSH, if PULL or ST is required:
a Switch power OFF
b Select arm configuration
c Switch power ON
After changing any system selection a new LEARN must be carried out.
44
Encoder
5 s
HOT
1.5 s
30 s
ON
1
2 3 4 5
POAS
CLTQ
HOT
Hold open time
Closing torque
Power assist
Issue 2021-02-24
Lock kick switch
Synchronizing of double doors
ON/OFF/HOLD open switch
LRN
LEARN BUTTON
24 V DC
LOUT
Lock-out for OPD (–)
OPD
Overhead presence detection/Mat safety
XIMP
Inner impulse controlled by
IIMP
Inner impulse
GND
Ground
Overhead presence detection (incl. 24 V, LOUT and
OPD
Safety Impulse)
LED
= ERROR
DIP-switches shown in
OFF position
PAG
MAT
SOS
ARM 1/2 Arm system setting
PUSH & GO
Safety mat
Stop on stall
PUSH
PULL
ST
4 5
4
5
4
5
1005088-en-22.0